摘要 目的考察并验证旧折叠式碘吸附器换炭再用的可行性。方法采用使用过的碘吸附器和"模拟使用过的碘吸附器"壳体进行两组换炭再用试验。结果被试验碘吸附器净化系数和阻力均满足核电站规定的技术指标的要求。结论使用过的折叠式碘吸附器壳体至少可以换炭再用三次以上,其性能良好。 Objective The folding iodine adsorber carbon was exchanged and then repeatedly used were researched.Methods Experiment of exchanging carbon for used and simulation used folding iodine adsorber were accomplished.Results The cleaning coefficient and pressure drop were satisfied technical requirement of nuclear power plant.Conclusion The used folding iodine adsorber could be repeatedly used over there times and have good performance.
出处 《中国辐射卫生》 2015年第6期673-675,共3页 Chinese Journal of Radiological Health
关键词 折叠式碘吸附器 净化系数 阻力 Olding Iodine Adsorber Cleaning Coefficient Pressure Drop
  • 相关文献

参考文献1

  • 1AFNOR.Nuclear Energy-Nuclear Ventilation-Testing Methods for Scrubbing Coefficient of Iodine Traps. AFNOR Standard NFM62-206 . 1984