摘要 对北京尘土中水溶性成分进行了分析测定 ,结果表明 :水溶性成分中含有K+ 、Na+ 、Ca2 + 、Mg2 + 、NH4 + 、SO4 2 - 、NO3- 、Cl- 、F- 、HCO3- 、NO2 - 等离子。对失效的连接器分析发现 :在电接触表面上有大量的污染物 ,腐蚀产物中含有K、Ca、S、Cl等尘土水溶性成分。 Analysis of the water soluble salts in airborne dust samples collected in Beijing has been carried out by various analytic methods, the results show that K +, Na +, Ca 2+ , Mg 2+ , NH 4 + , SO 4 2- , NO 3 -, Cl -, F -, HCO 3 - and NO 2 - exist in the water solution of dust. The failed connectors are inspected by scanning electron microscope and X ray energy spectroscope, serious contaminants are detected at the contact interfaces. The major elements of water soluble salts in dust such as K, Ca, S and Cl are found in part of the corrosion products. This paper discusses the corrosion effect of dust contamination on electric contact surfaces.
机构地区 北京邮电大学
出处 《机电元件》 2003年第2期11-14,18,共5页 Electromechanical Components
基金 国家自然科学基金资助项目 (5 0 2 770 0 2 )
关键词 连接器 电接触表面 尘土腐蚀 失效分析 electric contacts dust corrosion water soluble salts
  • 相关文献

参考文献13

  • 1A L 佩奇;R H 米勒.土壤分析法,1991.
  • 2林雪燕;章继高;Sugimura K.不同电镀层长期室内暴露后形成的腐蚀膜层的特点及其电接触性能,1996.
  • 3ZhangJ G;Liang Y N;Wan J W.Analysis of organic compounds in airborne dust collected in Beijing,1998.
  • 4Liang Y N;Zhang J G;Liu J J.Identification of inorganic compounds in dust collected in Beijing and their effects on electric contacts,1997.
  • 5Zhang J G;Wen X M.The effect of dust contamination on electric contacts,1986(01).
  • 6Zhang J G.Characteristics of dust deposition and the effect of dust on electric contacts,1986.
  • 7White L.Development of a new connector dust test,1987.
  • 8Frankenthal R P.Role of particle contamination in the corrosion of electronic materials,1992.
  • 9Mano K.Reliability of Contact Components,1981.
  • 10陈巍,郑冀.电接触材料腐蚀机制研究进展[J].电工材料,2010(3):3-8. 被引量:16