摘要
通过试验认为盐酸胍的存在对邻菲罗啉亚铁吸收曲线、吸光值稳定的pH范围、显色剂用量及有色物的稳定性等均无影响,并建立了邻菲罗啉分光光度法直接测定盐酸胍中微量铁含量的方法,当盐酸胍中铁的质量分数为5×10-6时,相对标准偏差为2%。
An analytical method,spectrophotometric determination of micro amount iron in guanidine hydrochloride with 1,10-phenanthroline,was established.When iron amount in the sample was 5×10-6,its relative standard deviation was 2%.It was proven that the relation curves between absorbance and wave length or acidity,1,10-phenanthroline,laid time were not affected by guanidine hydrochloride.
出处
《江苏工业学院学报》
2003年第1期33-35,共3页
Journal of Jiangsu Polytechnic University