期刊文献+

图像仿真在数字辐射成像系统指标估算中的应用 被引量:1

The use of image simulation on estimating indicators for digital radiograph system
下载PDF
导出
摘要 通过计算机模拟的方法改进了60Co集装箱检测系统的指标估算的方法,结果CI和IQI指标估算值与实测值较好地吻合。 CI (Contrast Indicator), IQI( Image Quality Indicator) and SP( Steel Penetration) are the important indicators in the digital radiograph system. The estimating of them takes an important status in the system performance design. At present the estimate method is lack of the support from experiment and the result is distinct from the measurement. This paper uses the computer simulation method to estimate the indicators of the 60Co container inspection system and gets a very good result.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2003年第4期321-323,320,共4页 Nuclear Electronics & Detection Technology
关键词 图像仿真 数字辐射成像系统 指标 估算 应用 集装箱检测系统 CI IQI digital radiograph computer simulation ^(60)Co container inspection system
  • 相关文献

参考文献4

  • 1盛骤 谢式千 等.概率论与数理统计(第二版)[M].北京:高等教育出版社,1989.279-284.
  • 2吴志芳,周立业,王立强,刘锡明.^(60)Co 集装箱检测系统中的图像处理[J].核电子学与探测技术,1999,19(1):30-33. 被引量:12
  • 3段福亮.数字信号处理C语言程序集[M].沈阳:辽宁科学技术出版社,1997..
  • 4安继刚 等.集装箱检测系统CI及IQI值的理论估算与实验测量[A]..第8届核电子学与核探测技术学术年会文集[C].,1996.9.

共引文献35

同被引文献3

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部