用蒙特卡罗方法对^(60)Co数字辐射成像系统检测射线束的准直研究 被引量:2

Study on Inspection Ray Collimation Process for ^(60)Co Digital Radiography System Using Monte Carlo Method
下载PDF
导出
摘要 应用蒙特卡罗方法模拟了60Co辐射成像系统检测射线束的准直过程。通过分析MCNP程序给出的计算数据,讨论了源室、准直器和侧屏蔽体在射线准直过程中的不同作用,对实现成像系统射线的准直具有参考价值。 The Monte Carlo method is used to simulate inspection ray collimation process for 60Co radiography system. According to the calculating results given by MCNP program, the influence of source chamber, collimator and shielding sideboard to inspection ray are discussed. The results have referential value to realize collimation design for radiography system.
出处 《同位素》 CAS 2003年第2期96-99,共4页 Journal of Isotopes
关键词 蒙特卡罗法 ^60Co数字辐射成像系统检测射线束 准直 检测 钴源 计算机模拟 Monte Carlo method ^(60)Co radiography system collimation dose distribution
  • 相关文献

参考文献3

  • 1安继刚,周立业,刘以思,邬海峰,吴志芳,向新程,王立强,张颜民,刘锡明,谈春明.钴-60集装箱检测系统[J].核技术,2002,25(6):430-436. 被引量:9
  • 2金文绵 李素梅 高彦锋.MCNP-3B/PC使用手册[Z]:核电软件中心入库资料NPSC 0364[M].,1995..
  • 3金文绵 李素梅 高彦锋.MCNP-3B/PC使用手册.核电软件中心入库资料,NPSC 0364,1995[Z].,..

二级参考文献1

共引文献8

同被引文献28

  • 1Botter-Jensen L, Hedemann Jensen H. Determi nation of scattered gamma radiation in the calibra tion of environmental dose rate meters[J]. Radia tion Protection Dosimetry, 1992, (4) :291-299.
  • 2PATEL NP, Majumdar B, Vijayan V. Study of scattered radiation for in-air calibration by a multi- ple distance method using ionization chambers and an HDR 192Ir brachytherapy source [J]. The British journal of radiology, 2006,79 : 347-352.
  • 3高飞.Co-60、Cs-137光子参考辐射场中散射辐射问题的蒙特卡罗方法研究[D].北京:中国原子能科学研究院,2009.
  • 4Ferreira LM. Dose determination by Monte Carlo-a useful tool in gamma radiation process[J]. Radia- tion Physics and Chemistry,2000, 57: 667-670.
  • 5Sohrabpoura M, Hassanzadehb M, Shahriarib M. Gamma irradiator dose mapping simulation using the MCNP code and benchmarking with dosimetry [J]. Applied Radiation and Isotopes, 2002, 57: 537-542.
  • 6Seidel K, Chen Y, Fischer U, et al. Measurement and analysis of dose rates and gamma-ray fluxes in an ITER shut down dose rate experiment[J]. Fu- sion Engineering and Design,2002,63-64:211 215.
  • 7Mark SW , Laurence FM. A comparison of Monte Carlo and model based dose calculations in radio- therapy using MCNPTV[J]. Nuclear Instruments and Methods in Physics Research A , 2006,562 : 1 013-1 016.
  • 8Hranitzky C, Stadtmann H. Monte Carlo Study of a 60Co Calibration Field of the Dosimetry Labora tory SEIBERSDORF[J]. Radiation Protection Do- simetry,2007, 125(1) :153-156.
  • 9Bgtter-Jensen L , Hedemann Jensen P. Determi- nation of scattered gamma radiation in the calibra- tion of environmental dose rate meters[J]. Radia lion Protection Dosimetry, 1992,42(4):291-299.
  • 10Selc J. Monte Carlo study of reference photon fields in the irradiation halls of the Czech Metrolo- gy Institute[J]. Nuclear Instruments and Meth- ods in Physics Research A, 2007,580:141-144.

引证文献2