摘要
对两段注汽管材料进行了宏观检察、化学成分、壁厚与管径测量、光学金相组织、常温机械性能、断口扫描电镜、能谱元素等试验分析 .结果表明 ,注汽管材料的局部腐蚀主要是氧化 -氯化腐蚀 .强度校核表明 ,两段注汽管目前的壁厚已不能满足内压P =17 2MPa、温度T =35
In this paper,a failure analysis was performed for materials of two section steam-injecting pipes,by means of examinations such as:macro-morphology、wall thickness and diameter、chemical composition、optical micrography、mechanical properties、scanning electron microscope(SEM) and EDS.The results show that the pipes suffered from an oxidation-chlorination corrosion.Residual strength caluculation shows that the wall thickness of the corroded two section steam-injecting pipes is below the requirement for further use according to the following designing criterion:P=17.2 MPa and T=354℃.
出处
《腐蚀科学与防护技术》
CAS
CSCD
北大核心
2003年第5期304-306,共3页
Corrosion Science and Protection Technology
关键词
热力采油
注汽管线
腐蚀
安全性分析
断口分桥
steam-injecting pipe
oxidation-chlorination corrosion
failure analysis