消火栓水枪喷嘴水力计算方法的简化

A Simplification of Method for Hydraulic Calculation of Water Gun Nozzles for Hydrants
下载PDF
导出
摘要 针对目前消火栓喷嘴水力计算采用试算及图表法所存在的问题,通过对原求解函数的优化拟合,推导出可直接计算的解析式,便于基层设计人员在实际工程设计中应用。对该解析式计算精度的分析表明,在常用参数范围内,最大拟合误差仅为1.49%,满足现行规范要求。 In view of the problems existing with the use of trial-calculation method and chart method in the hydraulic calculation of hydrant nozzles,an analytic equation which can be directly used in calculation is deduced through optimizing and fitting the original solving function,which can be easily applied by basic-level designers in practical engineering design.It is shown by the analysis of the calculation accuracy with the said analytic equation that within the range of normally-used parameters,the maximum fitting error is only1.49%,which satisfies the requirement in the current norms.
出处 《工业用水与废水》 CAS 2003年第4期62-64,共3页 Industrial Water & Wastewater
关键词 消防 消火栓 水枪 喷嘴 水力计算 fire fighting hydrant water gun nozzle hydraulic calculation
  • 相关文献

参考文献6

  • 1陈耀宗 姜文源.建筑给水排水设计手册[M].北京:建筑工业出版社,1994..
  • 2陈耀宗 姜文源 胡鹤钧 等.建筑给水排水设计手册[M].北京:中国建筑工业出版社,1994..
  • 3太原工业大学.建筑给水排水工程[M].北京:中国建筑工业出版社,1997..
  • 4蒋永琨.中国消防工程设计手册[M].北京:中国建筑工业出版社,1998..
  • 5太原工业大学 等.建筑给水排水工程[M].北京:中国建筑工业出版社,1997..
  • 6蒋永琨.中国消防工程设计手册[M].北京:中国建筑工业出版社,1998..