摘要
建立了测定化妆品中游离甲醛的衍生气相色谱法 ,方法最小检测量可达 5 75pg;在 8 3~ 1 66μg L浓度范围内 ,线性关系良好 ,回归方程Y =62 69X +7 897,r=0 9996 ;对于基质为有色或不透明的样品 ,本方法准确度显著高于乙酰丙酮分光光度法 (P <0 0 5)。本方法不受样品基质及试剂颜色等因素干扰 。
A method for determination of dissociate formaldehyde in cosmetics by derivative gas chromatography analysis was presented in the paper. The lowest detection limit of analysis was 5 75pg; the linear calibration curve for formaldenhyde were measured within the range of 8 3-166μg/L ,and the correlative coefficient was 0 9996. It was showed that this method was simple and easy to handle, and interferential factors were less, and accuracy was high.
出处
《卫生研究》
CAS
CSCD
北大核心
2003年第4期375-376,共2页
Journal of Hygiene Research
关键词
化妆品
游离甲醛
衍生气相色谱法
干扰因素
cosmetics, dissociate formaldehyde, derivative gas chromatograph