摘要 目的 :探讨带锁髓内钉在下肢骨干多节段骨折应用的临床疗效及有关问题。方法 :回顾性分析 31例股骨、胫骨干多节段骨折应用带锁髓内钉的临床资料 ,有关适应证、切开复位、扩髓及动力和静力固定问题进行讨论。结果 :31例中除 2例失访 ,2 9例随访 8~ 31个月 ,平均随访 12 .5个月 ,关节功能恢复优良率 93.1% ,骨折愈合率 98.3%。结论 :只有掌握好操作技术 ,带锁髓内钉是目前治疗下肢骨干多节段骨折的一种良好内固定方法 。 Objective:To study of clinical effect and related problems on fractures of Multi-portion of Shaft in Lower Extremity treaded with interlocking intramedullary nailing.Methods:To analyze the clinical data of 31 cases with interlocking intramedullary nailing in the femoral and tibia fractures of multi-portion retrospectively,to discuss questions on indication,open reduction,reaming marrow cavity,fixation of dynamic interlocking and fixation of static interlocking.Results:29 cases average follow-up period is 15 months(ranged 8 to 31 months).The excelent and good rate of joint function recovery is 93.1 %,the rate of union is 98.3 %.Conclusion:The interlocking intramedullary nailing is a good internal fixation for treatment of multi-portion fractures of shaft in lower extremity as long as operation techniqne being master.It would be widely used in clinical practice.
出处 《实用骨科杂志》 2003年第4期302-304,共3页 Journal of Practical Orthopaedics
关键词 带锁髓内钉 下肢骨干多段骨折 临床应用 疗效 适应证 内固定 Femoral fracture Tibia fracture Multi-portion fracture Interlocking intramedullary nailing
  • 相关文献

参考文献9

  • 1王宗仁,罗先正,刘长贵,李亚东.不扩髓带锁髓内钉治疗胫骨骨折(附43例报告)[J].骨与关节损伤杂志,2000,15(6):423-425. 被引量:89
  • 2罗先正,王宗仁.Crosse—Kempf带锁髓内钉的临床应用[J].中华骨科杂志,1993,13(3):173-175. 被引量:124
  • 3刘长贵,王宗仁.Grosse—Kempf带锁髓内钉治疗股骨、胫骨骨折[J].骨与关节损伤杂志,1996,11(5):282-284. 被引量:32
  • 4Gustilo RB,Merkow RL,Temple man D. Current concepts review, the management of open fracture [J]. J Bone Joint Surg, 1990,72A :299-302.
  • 5Browner BD. The science and practice of intramedullary nailing 2^nd edition [M]. Baltimore:willians &wilkins, 1996. 209.
  • 6Johner R, Wruh O. Classification of tibial shaft fractures and correlation with results after rigid fixation[J]. Clin Orthop, 1983,178 :7.
  • 7Duwedlius PJ,Schmidt AH,Rubinstein RA,et al. Nonreamed interlocking Intramedullary tibial nailing[J].Clin Orthop, 1995,315 : 104.
  • 8Wiss DA,Stetson WB. Unstaple fractures of the tibia treated with a reamed intramedullary interlocking nail[J]. Clin Orthop, 1995,315 : 56.
  • 9Odwyer KJ, Chakravarty RD, Esler CAN. Intramedullary nailing technique and its effect on union rates of tibia shaft fractures[J]. Injury, 1994,25(7):461.

二级参考文献1

  • 1Wu C C,Arch Orthop Trauma Surg,1992年,111卷,232页

共引文献230

同被引文献24

引证文献6

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部