期刊文献+

正常高值血压人群动脉弹性功能的变化 被引量:23

The Change of Artery Elastic Function in Persons with High-Normal Blood Pressure
下载PDF
导出
摘要 目的 观察正常高值血压人群大小动脉弹性功能指数C1、C2的变化。方法 本研究分三组 ,(1)正常血压组 :收缩压 (SBP) <130mmHg ,且舒张压 (DBP) <85mmHg ,入选 72例 ,男 37例 ,女 35例 ;(2 )正常高值血压组 :SBP130~139mmHg和 /或DBP85~ 89mmHg ,入选 6 0例 ,男 31例 ,女 2 9例 ;(3)高血压组 :SBP≥ 14 0mmHg和 /或舒张压≥ 90mmHg ,入选 6 3例 ,男 31例 ,女 32例。采用HDICVProfilorDO - 2 0 2 0动脉功能检测仪测定大小动脉弹性功能指数C1、C2。结果 正常高值血压人群的C1、C2比正常血压组低 (C1:11 9± 3 4VS 15 3± 4 5 ;C2 :4 0± 2 1VS 5 6± 2 6 ) ,P <0 0 1;比高血压组高 (C1:11 9± 3 4VS 9 4± 3 1;C2 :4 0± 2 1VS 2 8± 1 3) ,P <0 0 1。C1、C2与血压呈负相关 ,即随着血压的升高而下降。结论 正常高值血压人群的动脉弹性功能下降 ,与血压水平呈负相关 。 Objective To investigate the change of artery elastic function in persons with high-normal blood pressure.Method 195 subjects were enrolled and categorized into three groups:(1)normal blood pressure group(n=72):systolic blood pressure (SBP)<130mmHg,and disastolic blood pressure(DBP)<85mmHg;(2)high-normal blood pressure group(n=60):SBP130~139mmHg and/or DBP 85~89mmHg;(3)hypertension group(n=63):SBP≥140mmHg and/or DBP≥90mmHg.Artery elastic function C1 and C2 were measured by HDI CV Profilor DO-2020.Results C1 and C2 of high-normal blood pressure group were significantly lower than those of normal blood pressure group(C1:11 9±3 4 VS 15 3±4 5;C2:4 0±2 1 VS 5 6±2 6,P<0 01),and significantly higher than those of hypertension group(C1:11 9±3 4 VS 9 4±3 1;C2:4 0±2 1 VS 2 8±1 3,P<0 01).C1 and C2 were negatively correlattion with blood pressure,decreasing with BP ascending.Conclusions Artery elastic function in persons with high-normal blood pressure decreased and negatively correlated with BP.
出处 《心脑血管病防治》 2003年第4期11-13,共3页 CARDIO-CEREBROVASCULAR DISEASE PREVENTION AND TREATMENT
关键词 正常高值血压 动脉弹性功能 血压 收缩压 舒张压 High-normal blood pressure Artery elastic function Blood pressure
  • 相关文献

参考文献13

二级参考文献32

  • 1刘春萍,周书明,程友琴.动脉顺应性及其影响因素[J].中国动脉硬化杂志,2001,9(3):275-276. 被引量:32
  • 2孙宁玲 徐成斌主编.今日高血压[M].北京:中国医药科技出版社,1999.7.
  • 3Cohn J N.Vascular wall function as a risk marker for cardiovascular disease.Journal of Hypertension,1999,17(supp115):s41~s44.
  • 4McVeigh GE,Bratteli CW,Cohn JN,et al.Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis.Hypertension,1999,33:1392~1398.
  • 5Oparil S;Weber MH.Hypertension:a comparion to Brenner and Pector's the kindney.W.B.Saunders company,2000:134~151.
  • 6McVeigh GE,Burns DE,Fiokellstein SM,et al:Reduced vascular compliance as a marker for essential hypertension.American Journal of Hypertension,1991,4:245~257.
  • 7Cohn JN,Finkelstein SM,McVeigh GE,et al.Noninvasive pulse wave analysis for the early detection of the vascular disease.Hypertension,1993,26(3):503~508.
  • 8Zimmerman A,Vanhaker MD,Zakari A,et al.Loss of oscillatory arterial compliance detectable in young patients by radial artery pulse contour analysis.American Journal of Hypertension,2000,13(4,part2):B026.
  • 9Liang YL, Gatzka CD, Cameron JD, et al. Effect of heart rate on arterial compliance in men[J].Clin Exp Pharmacol Physiol,1999,26(4):342-346.
  • 10Brinton TJ, Kailasam MT, Wu RA, et al. Arterial compliance by cuff sphygmomanometer. Application to hypertension and early changes in subjects at genetic risk[J].Hypertension,1996,28(4):599-603.

共引文献991

同被引文献324

引证文献23

二级引证文献147

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部