期刊文献+

ECRH负高压脉冲电源系统控制特性研究 被引量:4

STUDY ON THE CONTROL PERFORMANCE OF THE NEGATIVE HIGH-VOLTAGE PULSE ROWER SUPPLY SYSTEM FOR ECRH
下载PDF
导出
摘要 负高压脉冲电源是ECRH系统最重要的组成部分之一。电源系统工作的可靠性与稳定性直接影响整个ECRH系统的运行。给出了电源系统各环节的动态数学模型,设计出带有前馈的PI调节器。利用MATLAB仿真确定了调节器参数。实验结果显示,该电源系统具有较好的控制特性。 Highvoltage power supply is one of the most important components in an ECRH system. Reliability and stability of highvoltage power distribution affect directly the running of the ECRH system. A mathematical model of the links of the power system is proposed in this paper. A PI adjuster with forward feedin has been designed. According to the MATLAB simulation, the parameter of the adjuster is fixed. Experimental results show that good controllable performance of the power supply has been obtained.
出处 《核聚变与等离子体物理》 CAS CSCD 北大核心 2003年第3期181-185,共5页 Nuclear Fusion and Plasma Physics
关键词 ECRH 负高压脉冲电源系统 控制特性 可靠性 稳定性 动态数学模型 电子回旋共振加热 PI调节器 ECRH High voltage pulse power supply Four poles valve MATLAB simulation
  • 相关文献

参考文献4

  • 1丁同海,刘保华,姜书方.ECRH负高压电源的反馈控制[J].核聚变与等离子体物理,2001,21(3):178-182. 被引量:9
  • 2杜少武,丁同海,徐宁,刘宝华.ECRH负高压脉冲电源系统的电磁兼容性研究[J].电力电子技术,2002,36(2):56-58. 被引量:8
  • 3Nerem A, Kellman D H, Pronko S G E, et al. Circuit Modeling and Feedback Controller Development of the 8.4 MW Modulator/Regulator Power System for the Electron Cyclotron Heating Facility Upgrade at D Ⅲ-D [A]. The 14th Topical Meeting on the Technology of Fusion Energy [C]. Park City:2000.10.
  • 4Pronko S G E, Baggest D. The 8.4 MW Modulator/Regulator Power Systems for the Electron Cyclotron Heating Facility Upgrade at D Ⅲ-D [A]. IEEE/NPSS Symp. on Fusion Engineering, Albuquerque [C]. New Mexico: 1999.

二级参考文献3

  • 1王小龙.80kV负高压脉冲电源的设计及实验鉴定部分[M].合肥:中国科学院等离子体物理研究所,1986..
  • 2王小龙,80kV负高压脉冲电源的设计及实验鉴定部分,1986年
  • 3吴昕,钱照明,庞敏熙,李俊明.开关电源印刷电路板EMC辅助设计的方法[J].电工技术学报,2000,15(4):62-66. 被引量:10

共引文献12

同被引文献30

  • 1苏禹,丁同海,刘保华.ECRH负高压电源系统信号隔离传输设计[J].计算机测量与控制,2004,12(10):972-974. 被引量:3
  • 2汪永军,胡纯栋,刘智民,刘胜.HT-7中性束注入装置数据采集系统的设计与应用[J].工业控制计算机,2004,17(8):64-65. 被引量:3
  • 3刘智民,刘小宁,陈联,宋士花,刘胜,胡纯栋.中性束注入器Tank充气特性对离子源放电的影响[J].真空科学与技术学报,2004,24(5):355-358. 被引量:7
  • 4杜少武,葛锁良,张健,刘保华,黄河.诊断中性束加速电源打火检测与保护电路的研究与设计[J].核聚变与等离子体物理,2005,25(4):290-294. 被引量:2
  • 5MICHE G,BRAND P,PEREVERZEV G,et al.Progress of the 10 MW ECRH system for W7-X[EB/OL].http:∥washop.free.fr/ec12/PAPERS.044-Michel.pdf.
  • 6PRONKO S G E,DELAWARE S,HARRIS T E,et al.The performance of 8.4 MW modulator/regulator power system for the electron cyclotron heating upgrade at DIII-D[C] ∥The 14th Topical Meeting on the Technology of Fusion Energy.Park City,Utah:[s.n.] ,2000.
  • 7NEREM A,KELLMAN D H,PRONKO S C E,et al.Circuit modeling and feedback controller development of the 8.4 MW modulator/regular power system for the electron cyclotron heating facility upgrade at DIII-D[C] ∥The 14th Topical Meeting on the Technology of Fusion Energy.Park City,Utah:[s.n.] ,2000.
  • 8PRONKO S G E,BAGGEST D S.The 8.4 MW modulator/regulator power system for the electron cyclotron heating upgrade at DIII-D[C] ∥The 18th IEEE/NPSS Symposium on Fusion Engineering.New Mexico,USA:[s.n.] ,1999.
  • 9DING Tonghai,DU Shaowu,LIU Baohua,et al.The high voltage power supply system of ECRH for HU-7[C] ∥Power Modulator Symposium,2002 and 2002 High-Voltage Workshop.[S.l.] :[s.n.] ,2002.
  • 10PRONKO S G E, BAGGEST D S. The 8.4 MW modulator/regulator power systems for the electron cyclotron heating facility upgrade at DIII-D [C].//The 18th IEEF/NPSS Symposium on Fusion Engineering. Albuquerque, New Mexico, USA:[s. n. ], 1999: 194-197.