摘要
采用烷基膦酸为载体的大块液膜体系处理含铜废水,研究了搅拌速度、料液相pH值、载体浓度、体系温度对Cu2+迁移的影响。结果表明,在搅拌速度为300~400r/min、料液相pH值控制在3.0~4.5、载体浓度为6.25%~7.5%、体系温度为288~308K的最佳工艺条件下,Cu2+的迁移率可达99.8%。
The effect of stirring speed, pH values in feed solution, concentrations of carrier and temperature of system on the transport of Cu2+ through the bulk liquid membrane with alkyphosphonic acid for copperelectroplating wastewater treatment has been studied in this paper. The results show that the transport rate of Cu2+ can reach 99.8% under the optimal technological conditions of stirring speed 300~400 r/min,pH values 3.0~4.5,carrier concentrations 6.25%~7.5% and temperature 288~308 K.
出处
《西安理工大学学报》
CAS
2003年第2期145-147,共3页
Journal of Xi'an University of Technology
关键词
大块液膜
烷基膦酸
镀铜废水
bulk liquid membrane
alkylphosphonic acid
copper-electroplating wastewater