摘要
提出了一种对RLC线性无源网络单、双重故障的诊断方法.论述了当可测端对各元件的转移阻抗已知时,根据两次或三次独立测试结果,可实现故障的定位和定值.
A method of single and double faults diagnosis in RLC linear network is pro posed.The faults can be located and valued based on the results of two or three independent measures when t he transfer of impedance at assessib le nodes is known.
出处
《南昌水专学报》
CAS
2003年第2期23-25,36,共4页
Journal of Nanchang College of Water Conservancy and Hydroelectric Power