摘要
针对由管理制度不健全、工艺和设备缺陷等原因引起的干熄焦发电量低的问题,采取了加强管理,加强技术改造等一系列措施,提高了干熄焦发电机组有功功率,日平均发电量及产汽量分别比2000年提高11516kW.h和145t。
Aiming at low generation ratio of CDQ steam turbogenerator sets caused by insufficient management and default of its process and equipment, a series of measures such as strengthening management and technical transformation etc. were adopted. Then CDQ steam turbogenerator sets active power increased and the daily average generation and vapor produced is increased by 11,516 kW.h and 145t separately than the amounts of 2000.
出处
《山东冶金》
CAS
2003年第4期27-28,共2页
Shandong Metallurgy
关键词
干熄焦
汽轮发电机组
有功功率
集汽包
管理制度
发电量
coke dry quenching
steam turbo-generator sets
active power
steam header
management system