期刊文献+

提高干熄焦汽轮发电机组有功功率措施

Measures to Increase CDQ Steam Turbo-generator Sets Active Power
下载PDF
导出
摘要 针对由管理制度不健全、工艺和设备缺陷等原因引起的干熄焦发电量低的问题,采取了加强管理,加强技术改造等一系列措施,提高了干熄焦发电机组有功功率,日平均发电量及产汽量分别比2000年提高11516kW.h和145t。 Aiming at low generation ratio of CDQ steam turbogenerator sets caused by insufficient management and default of its process and equipment, a series of measures such as strengthening management and technical transformation etc. were adopted. Then CDQ steam turbogenerator sets active power increased and the daily average generation and vapor produced is increased by 11,516 kW.h and 145t separately than the amounts of 2000.
出处 《山东冶金》 CAS 2003年第4期27-28,共2页 Shandong Metallurgy
关键词 干熄焦 汽轮发电机组 有功功率 集汽包 管理制度 发电量 coke dry quenching steam turbo-generator sets active power steam header management system