摘要 Root tensile strength is an important factor controlling the performance of bio-slope stabilization works. Due to evapotranspiration and climate factors, the root moisture content and its suction can vary seasonally in practice and may not equal soil suction. The influences of suction and root moisture contents were investigated on Chrysopogon zizanioides(vetiver grass) root tensile strength. The root specimens were equilibrated with moist air in different suction conditions(0, 10, 20, and 50 kPa), prior to root tension tests. The root-water characteristic curve or relationship between root moisture and suction, was determined. The increase in suction resulted in decreased tensile strengths of the grass roots, particularly those with diameter of about 0.2 mm, which constituted 50.7% of all roots. For 1 mm roots, the tensile strength appeared to be unaffected by suction increase. The average root tensile strengths were used to estimate the root cohesion in slope stability analysis to find variation of safety factors of a bioengineered slope in different suction conditions. The analysis showed that the critical condition of slope with the lowest factor of safety would happen when the soil suction was zero and the root suction was high. Such condition may occur during a heavy rain period after a prolonged drought. Root tensile strength is an important factor controlling the performance of bio-slope stabilization works. Due to evapotranspiration and climate factors, the root moisture content and its suction can vary seasonally in practice and may not equal soil suction. The influences of suction and root moisture contents were investigated on Chrysopogon zizanioides(vetiver grass) root tensile strength. The root specimens were equilibrated with moist air in different suction conditions(0, 10, 20, and 50 kPa), prior to root tension tests. The root-water characteristic curve or relationship between root moisture and suction, was determined. The increase in suction resulted in decreased tensile strengths of the grass roots, particularly those with diameter of about 0.2 mm, which constituted 50.7% of all roots. For 1 mm roots, the tensile strength appeared to be unaffected by suction increase. The average root tensile strengths were used to estimate the root cohesion in slope stability analysis to find variation of safety factors of a bioengineered slope in different suction conditions. The analysis showed that the critical condition of slope with the lowest factor of safety would happen when the soil suction was zero and the root suction was high. Such condition may occur during a heavy rain period after a prolonged drought.
出处 《Journal of Mountain Science》 SCIE CSCD 2019年第2期275-284,共10页 山地科学学报(英文)
基金 the financial supports from the Chaipattana Foundation Kasetsart University Research and Development Institute(KURDI) the scholarship for his PhD studies provided by the Faculty of Engineering,Kasetsart University
关键词 ROOT TENSILE strength Bio-slope stabilization SUCTION Vetiver Chrysopogon zizanioides ROOT reinforcement Root tensile strength Bio-slope stabilization Suction Vetiver Chrysopogon zizanioides Root reinforcement
  • 相关文献

参考文献3

二级参考文献22

共引文献34

同被引文献210

引证文献12

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部