以首都博物馆为例 ,阐述了博物馆建筑防火安全的特殊性。分别对该工程的消火栓系统、自动喷水灭火系统、水喷雾灭火系统、智能消防水炮系统、气体消防系统进行了介绍。
Special demands on fire protection of museum building were taken into consideration in practical design of the Capital Museum in Beijing. The design items of automatic sprinkling system, hydrant distribution, water fog sprinkler system, intelligent fire gun and gas fire control system for this project are presented. Some technical issues are discussed.
出处
《给水排水》
CSCD
北大核心
2003年第9期42-48,共7页
Water & Wastewater Engineering