期刊文献+

地下综合管廊室内施工环境危害识别 被引量:5

Indoor Atmosphere Hazard Identification in Urban Utility Tunnels Installation Construction
下载PDF
导出
摘要 在地下管廊的机电安装施工过程中,存在着许多危害施工人员职业安全的因素。通过对机电安装阶段地下综合管廊内影响施工人员职业安全的因素进行分析,提出应该对粉尘、一氧化碳、挥发性有机物(VOC)、氧气、温湿度进行职业安全检测,并参照现行相关标准确定了各个因素的接触限值或报警值,为相应的地下综合管廊环境探测和控制系统提供了有力的技术支撑。 In the mechanical and electrical installation process of urban utility tunnels,There are many factors that endanger the occupational safety and Health of construction workers. Through the analysis of the factors affecting the occupational safety and Health of construction workers in during the mechanical and electrical installation process,it is proposed that should detected dust,carbon monoxide,volatile organic compounds( VOC),oxygen,and temperature and humidity,and refer to the current relevant standards to determine the exposure limit or alarm value of various factor,all these are provide powerful technical support for the develop of environment detection and control instrument use in urban utility tunnels.
出处 《施工技术》 CAS 2018年第S1期642-644,共3页 Construction Technology
基金 中建股份科技研发计划资助(CSCEC-2016-Z-20)
关键词 地下综合管廊 施工环境 粉尘 VOC urban utility tunnels construction environment dust volatile organic compounds