某冰蓄冷工程采用钢筋混凝土结构蓄冰池,工程完工蓄水发现蓄冰池的墙体出现严重的渗漏水。从设计方案、施工工艺、成品保护三个方面详细分析了蓄冰池防水层出现渗漏的原因,并提出了预防措施。
Reinforced concrete structure ice storage tank is used for ice storage project. After the completion of the project,there is serious leakage of water in the ice storage tank. The causes of leakage in the waterproof layer of ice storage tank are analyzed from three aspects: design,construction technology and product protection,and preventive measures are put forward.
出处
《施工技术》
CAS
2018年第S1期1349-1351,共3页
Construction Technology
关键词
钢筋混凝土结构蓄冰池
设计方案优化
真空绝热保温板
聚脲防水涂料
reinforced concrete structure ice storage tank
design scheme optimization
vacuum insulation panels
polyurea waterproof coatings