摘要
装配式剪力墙结构是一种工业化生产产品,其施工工艺和现浇结构有较大的不同。装配式剪力墙预制外墙的现场安装,较普遍采用塔式起重机吊装,钢管进行临时支撑。因预制外墙的受风面积较大,有必要对其抗风压的稳定性进行验算,确保安装过程中的安全性。
The assembly shear wall is an industrial production,and its construction technology is different from the cast-in-place structure.The installation of precast external walls is generally supported by tower cranes and temporary support by steel pipes.Because the wind area of precast outer wall is large,it is necessary to check the stability of its wind resistance,so as to ensure the safety during installation.
作者
陈骏
万大勇
程剑
伍永祥
余祥
CHEN Jun;WAN Dayong;CHENG Jian;Wu Yongxiang;Yu Xiang(The First Construction Engineering Limited Company of China Construction Third Engineering Bureau,Wuhan,Hubei 430040,China)
出处
《施工技术》
CAS
2018年第A04期572-574,共3页
Construction Technology
基金
国家重点研发计划资助:预制装配式混凝土结构标准化
工具化安装关键技术研究与应用(2016YFC0701906)
关键词
装配式
剪力墙结构
现场安装
风荷载
稳定
precast
shear wall structure
site installation
wind load
stability