摘要
随着原油劣质化的加剧,芳烃抽提装置原料中携带的氯离子数量呈上升趋势,氯离子对设备焊缝的腐蚀以及氯离子与环丁砜发生化学反应,加剧了环丁砜化学分解出酸性物质,对各类设备造成了叠加腐蚀,导致了装置包括重沸器在内的各类设备腐蚀泄漏增多。及时的判断、发现隐蔽的重沸器漏点,对对整套装置的安全生产就十分重要。
The chloride ions rise in feedstock of aromatics extraction unit as crudes' quality worsens,which will result in corrosion of welding in equipment and react with sulfolane to produce acid for further corrosion,which will lead to more leakage of equipment such as reboiler in the unit.Therefore,it's critical for the process safety of the whole unit to find out the hidden leakage in the reboiler timely.
出处
《石化技术》
CAS
2015年第9期53-,共1页
Petrochemical Industry Technology
关键词
重沸器
泄漏
氯离子腐蚀
快速判断
reboiler
leakage
chloride ion corrosion
rapid judgment