摘要 目的:探讨3D打印技术在粉碎性颧骨颧弓骨折治疗中的应用价值。方法:选择2014年1月—2017年4月期间在西安交通大学口腔医院就诊的单侧粉碎性颧骨颧弓骨折21例。术前行薄层CT扫描,并将CT数据导入计算机辅助设计软件;进一步在计算机中将健侧颧骨颧弓镜像至患侧,最终打印出"复位"理想的患侧颧骨颧弓形态模型。在此模型上,进行内固定钛板预成型。术中利用预成型的内固定钛板引导骨段复位并最终完成内固定。术后行CT复查,三维测量颧骨颧弓位置并与术前设计位置进行比较,评估手术效果。采用SPSS 25.0软件包对测量数据进行配对t检验。结果:术后关键标志点间距同术前设计差异无统计学意义,手术效果满意。结论:3D打印技术有助于术前设计和植入物精确塑形,能有效提高单侧粉碎性颧骨颧弓骨折复位的精确性。 PURPOSE:To explore the validity of 3 D printing technique in the treatment of unilateral comminuted zygomatic bone fracture.METHODS:Twenty-one patients with unilateral comminuted zygomatic bone fracture were included in the present study,which were treated from hospital January 2014 to April 2017.All patients underwent CT scan and the data were imported in Mimics 10.01 software.The zygomatic bone of healthy side was mirrored to the fracture side to rebuild a'perfect'reduction model.Bone fixation plates were pre-modeled on the model printed by a 3 D printing machine and used for bone reduction and fixation during operation.Three dimensional measurements were performed to evaluate the validity of 3 D printing based on pre-and post-operative three dimensional CT model.SPSS25.0 software package was used to perform paired t test on the measured data.RESULTS:No significant difference were observed between postoperative CT model and preoperative'perfect'reduction model.All patients were satisfied with their facial appearance.CONCLUSIONS:3 D printing technique is helpful to improve the accuracy of reduction of unilateral comminuted zygomatic bone fracture via preoperative pre-modeling.
作者 李立峰 屠军波 侯成群 虎小毅 LI Li-feng;TU Jun-bo;HOU Chen-qun;HU Xiao-yi(Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research,College of Stomatology,Xi'an Jiaotong University,Xi'an 710004,Shaanxi Province,China;Department of Oral Maxillofacial Surgery,College of Stomatology,Xi'an Jiaotong University,Xi'an 710004,Shaanxi Province,China)
出处 《上海口腔医学》 CAS CSCD 北大核心 2019年第2期154-157,共4页 Shanghai Journal of Stomatology
基金 陕西省重点研发计划(2017ZDXM-SF-108)
关键词 3D打印 粉碎性颧骨颧弓骨折 预成型 3D printing Comminuted zygomatic bone fracture Pre-fabrication
  • 引文网络
  • 相关文献

参考文献4

二级参考文献14

  • 1Lee JK, Jung PK, Moon CH. Three-dimensional cone beam com- puted tomographic image renrientation using soft tissues as re- ference for facial asymmetry diagnosis [ J ]. Angle Orthod, 2014, 84(1) : 38 -47.
  • 2Damstra J, Fourie Z, De Wit M, et al. A three-dimensional com- parison of a morphometric and conventional cephalometric midsa- gittal planes for craniofacial asymmetry [ J ]. Clin Oral Investig, 2012, 16(1) : 285 -294.
  • 3Jacobson A. Radiographic cephalometry: from basics to videoima- ging[M]. Chicago: Quintessence Pub. Co, 1995: 322.
  • 4Baek C, Paeng J, Lee JS, et al. Morphologic evaluation and clas- sification of facial asymmetry using 3-dimensional computed tomo- graphy[ J]. J Oral Maxillofac Surg, 2012, 70(5) : 1161 -1169.
  • 5Y6fiez-Vico RM, Iglcsias-Linares A, Torres-Lagares D, et al. Three-dimensional evaluation of craniofacial asymmetry : an analy- sis using computed tomography[ J]. Clin Oral Investig, 2011, 15 (5) : 729 -736.
  • 6Kim H, Kim BC, Kim J, et al. Construction and validation of the midsagittal reference plane based on the skull base symmetry for three-dimensional cephalometric craniofacial analysis [ J ]. J Craniofac Surg, 2014, 25(2) : 338 -342.
  • 7Hwang JJ, Kim K, Park H, et al. Factors influencing superimpo- sition error of 3D cephalometric landmarks by plane orientation method using 4 reference points : 4 point superimposition error re- gression model[J]. PLoS One, 2014, 9(11 ) : e110665.
  • 8de Momi E, Chapuis J, Pappas I, et al. Automatic extraction of the mid-facial plane for cranio-maxiUofacial surgery p!.anning[ J ]. Int J Oral Maxillofac Surg, 2006, 35 (7) : 636 -642.
  • 9Da NM, Soares AC, de Oliveira LC, et al. Evaluation of cephalo- metric landmark identification on CBCT multiplanar and 3D recon- structions[J]. Angle Orthod, 2015, 85 ( 1 ) : 11 - 17.
  • 10Hassan B, Nijkamp P, Verheij H, et al. Precision of identifying cephalometric landmarks with cone beam computed tomography in vivo[J]. Eur J Orthod, 2013, 35(1): 38-44.