期刊文献+

电化学方法在食品化学污染物快速检测中的研究进展 被引量:13

Recent advances on rapid detection of food chemical contaminants based on electrochemical methods
下载PDF
导出
摘要 近年来,食品化学污染物的有效控制与快速、灵敏检测受到了政府和民众的高度重视。传统的分析检测方法存在检测时间长、样品前处理复杂等缺点,难以满足实际检测的需求。电化学方法由于其仪器简单、分析速度快、检测灵敏度高等优点在食品化学性污染物检测方面越来越受到关注。本文介绍了电化学检测方法的主要类型及其基本原理,重点阐述了电化学分析方法在食品中重金属、农药、抗生素等化学残留物检测中的应用研究。最后,文章还对电化学方法在食品安全快速检测领域中的发展趋势进行了展望。 In recent years, the effective control and rapid, sensitive detection of in foods have been paid great attention by the government and the people. Traditional methods for chemical contaminants detection have some deficiencies including long detection time, and tedious sample preparation. It is difficult to meet the needs of actual testing. Electrochemical methods, due to its features of simple instrumentation, quick analysis speed, and high sensitivity, have been widely applied in detection of chemical contaminants in foods. This ar-ticle described the basic principles and main types of electrochemical methods, and further summarized the ap-plication of electrochemical methods in detection of heavy metals, pesticides, antibiotics and other chemical contaminant residues in foods. Finally, the future development of electrochemical methods for rapid detection of food safety was also prospected.
出处 《食品安全质量检测学报》 CAS 2014年第7期1937-1942,共6页 Journal of Food Safety and Quality
基金 国家自然科学基金项目(21205050) 中国博士后基金项目(2012M511224) 江苏大学高级人才引进启动基金项目(12JDG038)~~
关键词 电化学方法 食品化学污染物 快速检测 electrochemical method food chemical contaminants rapid detection
  • 相关文献

参考文献8

  • 1Maryam Najafi,Mohammad A. Khalilzadeh,Hassan Karimi-Maleh.A new strategy for determination of bisphenol A in the presence of Sudan I using a ZnO/CNTs/ionic liquid paste electrode in food samples[J].Food Chemistry.2014
  • 2Abbas Afkhami,Hamed Ghaedi,Tayyebeh Madrakian,Majid Rezaeivala.Highly sensitive simultaneous electrochemical determination of trace amounts of Pb(II) and Cd(II) using a carbon paste electrode modified with multi-walled carbon nanotubes and a newly synthesized Schiff base[J].Electrochimica Acta.2013
  • 3Guilin Xu,Hongli Zhang,Min Zhong,Tingting Zhang,Xiaojing Lu,Xianwen Kan.Imprinted sol–gel electrochemical sensor for melamine direct recognition and detection[J].Journal of Electroanalytical Chemistry.2014
  • 4P. Raghu,T. Madhusudana Reddy,K. Reddaiah,B.E. Kumara Swamy,M. Sreedhar.Acetylcholinesterase based biosensor for monitoring of Malathion and Acephate in food samples: A voltammetric study[J].Food Chemistry.2013
  • 5吴小娟,蔡健荣,韩恩,周立娜,陈铭枫.同位镀铋方波溶出伏安法检测蜂蜜中的痕量铅[J].食品安全质量检测学报,2012,3(5):457-461. 被引量:3
  • 6Meirong Wang,Huimin Kang,Dan Xu,Chengyin Wang,Shuzhao Liu,Xiaoya Hu.Label-free impedimetric immunosensor for sensitive detection of fenvalerate in tea[J].Food Chemistry.2013(1)
  • 7Wen-Jie Jin,Gong-Jun Yang,Hong-Xia Shao,Ai-Jian Qin.A novel label-free impedimetric immunosensor for detection of semicarbazide residue based on gold nanoparticles-functional chitosan composite membrane[J].Sensors & Actuators: B Chemical.2013
  • 8Vinod Kumar Gupta,Mehmet Lütfi Yola,Necip Atar.A novel molecular imprinted nanosensor based quartz crystal microbalance for determination of kaempferol[J].Sensors & Actuators: B Chemical.2013

二级参考文献4

共引文献3

同被引文献143

引证文献13

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;