期刊文献+

电感耦合等离子体质谱法测定扇贝中铅、砷、镉含量的不确定度评定 被引量:8

Uncertainty evaluation for determination of lead,arsenic and cadmium in scallop by inductively coupled plasma-mass spectrometry
下载PDF
导出
摘要 目的评定采用电感耦合等离子体质谱法(inductively coupled plasma-mass spectrometry,ICP-MS)检测扇贝中铅、砷、镉含量的不确定度。方法分析整个测量过程中存在的不确定度因素,包括测量重复性、称样量、稀释体积、标准溶液、标准曲线拟合以及方法回收率等,建立数学模型,对测量结果的不确定度进行评定。结果影响测量结果的不确定度主要来源于测量重复性、样品前处理和标准曲线拟合。扇贝样品中结果表示分别为:铅含量(1.82±0.33)mg/kg;砷含量为(3.43±0.35)mg/kg;镉含量为(1.32±0.17)mg/kg,k=2。结论该方法准确度高,适用于扇贝中重金属元素的检测,为提高数据准确性提供有效指导。 Objective To evaluate the uncertainty of determination of lead,arsenic and cadmium content in scallops by inductively coupled plasma-mass spectrometry.Methods The uncertainty factors in the whole measurement process were analyzed,such as the repeatability of samples,sample volume,dilution volume,standard solution,standard curve fitting and method recovery rate.The mathematical model of uncertainty evaluation was established for evaluating the uncertainty of measurement results.Results The uncertainties affecting the measurement results mainly came from measurement repeatability,sample preparation and standard curve fitting.The results of the scallop samples were as follows:lead content was(1.82±0.33)mg/kg,arsenic content was(3.43±0.35)mg/kg,cadmium content was(1.32±0.17)mg/kg(k=2).Conclusion This method has high accuracy and is suitable for detecting heavy metal elements in scallops,and which can provide effective guidance for improving data accuracy.
作者 张梅超 慕金雨 王妍 郐鹏 王楠 ZHANG Mei-Chao;MU Jin-Yu;WANG Yan;GUI Peng;WANG Nan(Weihai Institute for Food and Drug Control,Weihai 264200,China)
出处 《食品安全质量检测学报》 CAS 2019年第17期5884-5888,共5页 Journal of Food Safety and Quality
关键词 扇贝 电感耦合等离子体质谱法 不确定度 scallop lead arsenic cadmium inductively coupled plasma-mass spectrometry uncertainty
  • 相关文献

参考文献11

二级参考文献115

共引文献166

同被引文献82

引证文献8

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部