期刊文献+

阻垢缓蚀剂对不锈钢管缓蚀效果的评定方法 被引量:2

Evaluation of the effects of scale-corrosion inhibitors on stainless steel
下载PDF
导出
摘要 用点蚀电位法和失重法评价了七种阻垢缓蚀剂在不同冷却水样中对不锈钢的缓蚀效果。用腐蚀失重法评价阻垢缓蚀剂对不锈钢的缓蚀效果,既不合理也很难测准。点蚀电位法是评价阻垢缓蚀剂对不锈钢缓蚀效果的有效方法,但要选择合适的空白水样。 Seven scale-corrosion inhibitors have been tested in several kinds of cooling water.The effects of scale-corrosion inhibitors on stainless steel have been evaluated with pitting potential and weight loss measurements .Weight loss measurement used here is not reasonable and cannot give an exact result.It is believed that the pit-ting potential measurement is very effici ent for evaluating the effects of the scale-corrosion inhibitors on stainless steel,but a suitable blank water sample must be chosen.
出处 《工业水处理》 CAS CSCD 2003年第9期26-28,共3页 Industrial Water Treatment
关键词 阻垢缓蚀剂 不锈钢管 缓蚀效果 评定 点蚀电位法 失重法 腐蚀失重法 水资源 水处理 stainless steel scale-corrosion inhibitors pitting potential weight loss cooling wat er
  • 相关文献

参考文献8

二级参考文献41

  • 1周国定.交流阻抗法在电力设备腐蚀研究中的应用[J].中国电力,1994,27(10):24-29. 被引量:12
  • 2俞茂铮,姚秀平,汪国山,孙长海,许占豪,王乐天,谭顺科,彭虎劳,何显富,许晔.大功率汽轮机凝汽器汽相流动与传热特性的数值分析[J].动力工程,1995,15(6):42-49. 被引量:48
  • 3黄湘.上安电厂采用ANSALDO不锈钢管凝汽器[J].电力设计热机通讯,1989,(1).
  • 4王杏卿.热力设备的腐蚀与防护[M].水利电力出版社,1994.138-143.
  • 5吴曼倩,电站辅机,1997年,4期
  • 6杨武.金属的局部腐蚀[M].北京:化学工业出版社,1993.316.
  • 7化工设计全书编辑委员会.换热器设计[J].上海:上海科学技术出版社,1984.
  • 8张万峰译.凝汽器和其它热交换器管的VGB准则[J].电力设计水处理技术,1991,(2).
  • 9GEMoller.Seminarproceedings:PreventionofCondensersFailures—theStateoftheArt[R].EPRI-CS-4329-SR.Dec.1985.section7.
  • 10BechtelNationalInc.Steam-plantSurface-condenserLeakage—studyUpdate[R].EPRI-NP-2062,Finalreport,May1982.