摘要 连州发电厂420t/h燃煤锅炉投产运行了两年多,其省煤器泄漏现象相当严重。为此,对省煤器泄漏的原因进行了分析,详细分析了烟气流速、飞灰浓度和受热面布置形式等对省煤器磨损的影响。根据发电厂的实际情况,对省煤器的改造进行了探讨,提出采用膜式省煤器可以较好地解决泄漏问题,并给出具体实施方案。 The leakage of the economizers in 420 t/h boilers in Lianzhou Power Plant becomes very severe after twoodd years service of the boilers.This paper analyzes the causes of the leakage,putting emphasis on the effects of flue gas velocity,fly ash concentration and heating surface layout,etc.on the abrasion of the economizers.According to the circumstances of the plant,the use of the membrane type economizer is suggested as a solution,and specific retrofitting plan is given.
作者 杨建球
机构地区 连州发电厂
出处 《广东电力》 2003年第4期79-81,84,共4页 Guangdong Electric Power
关键词 420T/H锅炉 省煤器 泄漏 技术改造 连州发电厂 economizer wear leakage retrofitting
  • 相关文献

参考文献4

  • 1南京工业大学 西安交通大学热能动力热能教研室.电厂锅炉原理[M].北京:电力工业出版社,1980..
  • 2巴布克科-威尔科克斯公司.蒸汽的发生与应用[M].北京:兵器工业出版社,1990..
  • 3广东省电力试验研究所.连州发电厂1号机组性能试验报告汇编(锅炉专业)[R].广州:广东省电力试验研究所,2001..
  • 4广东省电力试验研究所.连州发电厂1号机组性能试验报告汇编(锅炉专业)[R].广州:广东省电力试验研究所,2001..