期刊文献+

CO_2压缩机跳车原因分析及处理

Analysis on CO_2 Compressor Shutdown and Its Treatment
下载PDF
导出
摘要 就CO2压缩机冬季开车过程中多次出现跳车的原因进行了分析,通过数据说明引起CO2压缩机跳车的主要原因是冬季气温较低,CO2经节流降温后,饱和水蒸汽结冰,引起堵塞,使CO2难以进入压缩机,造成联锁跳车,并提出了防范措施。 CO 2 compressor shutdown causes when sta rted up in the winter are analyzed in t he paper.Data shows that the main rea son for the shutdown is the low temperature i n the winter.After CO 2 is throttled and cooled down by four-to-one valve and the temperature is reduced to below 0℃,causing the saturated steam in the CO 2 to freeze and blocking foam-cleanin g apparatus of the 1st stage inlet separator and it is difficult for CO 2 to enter the compressor,which bring about low pressure on CO 2 inlet and shutdown of the compressor.If some measures are taken in the run,the problem of low pressure and sequential shutdown can be solved completely during the winter run.
出处 《化工生产与技术》 CAS 2003年第4期47-48,共2页 Chemical Production and Technology
关键词 CO2压缩机 跳车 防范措施 尿素 CO 2 compressor,shutdown,cause analysis,protection measures
  • 相关文献