摘要 在利用压滤技术分离Fv时,时常会出现过滤时间长,Fv沉淀中液体含量高及沉淀冻存到温时间长的情况。经研究发现,上述情况主要受Fv制作时缓冲液添加速度及过滤时压滤机进液压强的影响。在其他工艺参数不变的情况下,改变缓冲液加液速度及进液压强。经多批次生产统计发现,在平均加液速度为36L/h及进液压强为160k Pa时,能大幅缩短过滤时长,减少沉淀中液体含量,缩短沉淀冻存到温时间。此工艺对缩短生产周期,降低能耗有重要意义。 During filtering Fv with pressure filtration technique, if the filter time is too long, Fv precipitations with high liquid content and the precipitations freeze-stored to the specified temperature with a long time happen frequently.The study found that those were influenced by the speed of adding buffer in manufacturing Fv and the liquid inlet pressure. In the case of other parameters constant, the speed of adding buffer and the liquid inlet pressure were changed. The statistics with multi-batch of production showed that it could reduce the filtration time, the liquid content of precipitations and the time of precipitations freeze-stored to the specified temperature with the speed of adding buffer 36.0L/h and the liquid inlet pressure 160 k Pa. It has an important significance to reduce production time and energy consumption.
出处 《生物化工》 2016年第5期33-35,共3页 Biological Chemical Engineering
关键词 人血白蛋白 FV 加液速度 进液压强 过滤时长 Human Albumin Fv Speed of Adding Buffer Feed Pressure Filtration Time
  • 相关文献

参考文献3

二级参考文献15

  • 1柏乃庆.血液成份,衍生物.输液治疗科学出版社,1989.23.
  • 2周明忠.利凡诺法分离白蛋白和丙球蛋白的体会[J].中华血液学杂志,1991,1:33-33.
  • 3叶景珍译.用聚乙二醇法回收白蛋白简便方法[J].国外医学:输血及血液学分册,1989,1:134-134.
  • 4袁庆辉.加热PEG法-另一种血浆分离法[J].国外医学生物制品分册,1987,7(1):238-238.
  • 5长春生物制品所.白蛋白工艺简介[J].输血及血液学,1986,1:15-15.
  • 6中国生物制品标准化委员会,中国生物制品规程,2000年,319-321,328-331页
  • 7刘隽湘,输血疗法与血液制剂,1996年,159页
  • 8FDA.Biological Product Deviation Reports[].Annual Sum-maryfor Fiscal Year.2006
  • 9.
  • 10.

共引文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部