摘要 利用电流型闪烁探测器采用直照法测量零功率堆装置的瞬发中子时间系数α时,由于示波器基线旋转导致产生测量误差。通过采用数学分析方法对误差进行分析计算,得到该误差呈现一阻尼震荡波形。当基线旋转约为θ=±5°,最大的差别与设计值相差1μs-1,正负极差可达1.5μs-1。通过合理选取实验数据拟合时间段,即可消除该误差,提高实验数据的可靠性。 Using the method of irradiating the zero-power device directly, the neutron decay constant was measured with the ST-PMT detector system. During the measuring display, there were some errors exicted because of the base-line rotation in the oscilloscope display. The shape of errors was displied in the formation of damped vibration.When the value of base-line rotation in the oscilloscope is about ±5°,the max data of neutron decay constant error is 1 μs-1 and the maximum error both the position and the negation is 1.5 μs-1. The errors are eliminated by chosen the duration of the experiment data reasonably.
出处 《中国测试》 CAS 北大核心 2015年第3期18-21,共4页 China Measurement & Test
关键词 瞬发中子时间系数 电流型闪烁探测器 基线旋转 误差 阻尼震荡 the neutron decay constant ST-PMT base-line rotation error damped vibration
  • 相关文献

参考文献5

  • 1[美]普罗菲奥(A·E· Profio) 著,徐济鋆,刘竞成 译.实验反应堆物理学[M]. 原子能出版社, 1980
  • 2Gathers G R.Recovery of time-varying exponential signals and other rapidly developing functions. Nuclear Science and Engineering . 1988
  • 3Longley H.Numerical solutions and applications of the fold integral. Los alamos scientific laboratory Rept.LA-2729 . 1982
  • 4Minnet T Y.Godiva-II-An Unmoderated Pulse-Irradiation Reactor. Nuclear Science and Engineering . 1960
  • 5Orndoff J D.Prompt neutron periods of metal critical assemblies. Nuclear Science and Engineering . 1975