摘要
该文根据新实施的JJG700——2016检定规程的新要求和新变化,结合不确定度测量的分析,全面讨论和研究气相色谱仪火焰离子化检测器检出限的测量不确定来源和影响程度,并对其进行全面的评定分析,从而为气相色谱仪离子化检测器的检定和使用者提供参考。
According to the new requirements and new changes of the newly implemented JJG700-2016 verification protocol,combined with the analysis of uncertainty measurement,a comprehensive discussion and study of the uncertainty of the detection limit of gas chromatograph flame ionization detector and the degree of influence was done,and a comprehensive assessment of its analysis was conducted,thus a reference was provided for the verification and use of gas chromatography ionization detector.
出处
《中国测试》
北大核心
2017年第S1期21-23,共3页
China Measurement & Test
关键词
气相色谱仪
火焰离子化检测器
检出限
不确定度
gas chromatographs
flame ionization detector
detection limit
uncertainty