期刊文献+

基于熔融制样测量钛铁中5种成份的研究 被引量:11

Analyze the content of 5 elements in Ti-Fe based on melting method
下载PDF
导出
摘要 为了制备出适合X射线荧光光谱分析的玻璃片,采用两步法对钛铁样品进行熔融制样。首先对钛铁样品进行预氧化,其次对预氧化后的样品进行硼酸盐熔融制备出玻璃片。通过优化制备石墨垫底坩埚和助熔剂称样量,制备出适合X射线荧光光谱分析的玻璃片,该方法能够快速准确分析钛铁中5种元素的含量,克服了铂金坩埚不能直接用来熔融铁合金的缺陷。 In order to prepare a glass plate suitable for X-ray fluorescence spectroscopy analysis,a two-step method was used to melt the Ti-Fe sample. Firstly,the samples were pre-oxidized,and then the glass plate were prepared by borate fusion. By optimizing the preparation of graphite bottom crucible and flux weight,a glass plate suitable for X-ray fluorescence spectrometry analysis was prepared,which can quickly and accurately analyze the content of 5 elements in Ti-Fe and overcome the defects of the platinum crucible which could not be directly used for melting ferroalloy.
出处 《中国测试》 北大核心 2017年第S1期68-71,共4页 China Measurement & Test
关键词 X射线荧光光谱仪 熔片法 钛铁 X-ray fluorescence spectroscopy melting method ferrotitanium
  • 相关文献

参考文献1

二级参考文献14

  • 1Berube L. XRF and AA/ICP analysis of FeCr.. The power of borate and peroxide fusion sample prepara- tion[C], The Fifteenth CSM Conference Exhibition on Analysis Testing of Metallurgy Materials Pr- ceeedings, Beiiing, China. 2010.
  • 2Corporation Scientifique Claisse. Glass disks and so lutions by fusion for users of Claisse fluxers:2nd edi- tion[M]. 2003: 67.
  • 3Eivindson T, Mikkelsen O. Problems by usingpressed powder pellets for XRF analysis of ferrosili- con alloys[J], Advances in X-Ray Anal. , 2001,44: 409-418.
  • 4Lupton D F. et al. The correct use of platinum in the XRF laboratory[C]. 19th Durham Conference on X- Ray Analysis, Durham, England, 1995.
  • 5Berube L, Minimizing time and manipulations for the preparation of ferroalloys by fusion[C]. Duisburg X- Ray Fluorescence User Meeting, Duisburg, Germa- ny, 2007..
  • 6Berube L. Borate fusion of samples containing semi J non oxidized element: The solid dry oxidation tec nique['C]. Denver X-Ray Conference, Denver, USA 2006. 1.
  • 7Coedo A G, Dora T,Padilla I, et al. X-ray fluores- cence determination o major and minor elements in ferrotitanium, ferroniobium and ferrovanadium fromcompressed pellets and fusion beads[J]. X-Ray Spec- trom. , 2002,31(6) :424-431.
  • 8ISO-4173, Ferromolybdenum: Determination of mo- lybdenum content - Gravimetric method[S], 1980.
  • 9Gagnon J-P, Oendreau L. Evaluation of an electric fluxer[J], International Cement Review, 2007, 8 75-78.
  • 10Corporation Scientifique Claisse. ASTM C-114 Qualification test method to improve analytical re- sults using th fused beads technique[S], ICMA, 2001.

共引文献1

同被引文献73

引证文献11

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部