期刊文献+

CC及ACQ-B防腐剂处理木材的抗流失试验 被引量:4

Leachability determination on Lumber Treaded with CC and ACQ-B
下载PDF
导出
摘要 对于氨溶性季铵铜 ACQ- B处理的马尾松 (Pinus massoniana)及尾叶桉 (Eucalyptus urophylla)试材 ,在吸药量为 3.0~ 6 .0 kg/ m3时 ,按标准 AWPA M11- 87测定的流失率小于 2 .5 0 %。比较 ACQ- B与 CC两种处理材 ,当吸药量(以 Cu O计 )相当时 ,CC的流失率较 ACQ- B大。ACQ- B可用于与地接触的人工林木材处理 。 Leaching test was conducted according to AMPA M11 87 standard. Pinus massoniana and Eucalyptus urophylla were treated with ammoniacal copper quat type B (ACQ B), copper citrate (CC) and chromated copper arsente type C (CCA C). Leachability determination results showed that the leaching rate was less than 2.5% for the wood treated with ACQ B at the retention of 3.0~6.0 kg/m 3. The anti leachablitity of wood treated with ACQ B was better than that treated with CC, because the leaching rate of wood treated with ACQ B was lower than that treated with CC at almost same copper retention level (as copper oxide). ACQ B was a potential wood preservative for plantation wood used in the ground field such as agricultural and building wood.
作者 蒋明亮 王平
出处 《木材工业》 2002年第2期35-36,共2页 China Wood Industry
基金 国家自然科学基金 (3 980 0 114 )项目部分内容
关键词 氨溶性季铵铜 马尾松 尾叶桉 木材 防腐处理 抗流失试验 柠檬酸铜 防腐剂 Copper citrate (CC) Ammoniacal copper quat type B (ACQ B) Leaching test
  • 相关文献

参考文献5

  • 1Slahor J J, Hassler C C, DeGroot R C, et al. Preservative Treatment Evaluation of Red Maple and Yellow Poplar with ACQ-B[J]. Forest Prod. J., 1997, 47(4): 50~54.
  • 2Permadi P, DeGroot R C, Woodward B. Alternative Wood Preservatives for Use in Indonesia[J]. Forest Prod. J., 1998, 48(11/12): 98~101.
  • 3DeGroot R C, Carwford D W, Norton J, et al. Five-year Field Trials Using Preservative-treated, Second-growth Douglas-fir Exposed in Ground Contact in Australia [J]. Forest Prod. J., 2000, 50(2): 46~53.
  • 4Lebow S. Leaching of Wood Preservative Components and Their Mobility in the Environment[R]. USDA, Forest Products Laboratory, General Technical Report, 1993, FPL-GTR-93, 1-36.
  • 5AWPA Standards, A11-87, Standard Method of Determining the Leachability of Wood Preservatives [S]. 1987.

同被引文献55

  • 1金重为,施振华,张祖雄.ACQ木材防腐剂及防腐处理木材[J].木材工业,2004,18(4):34-36. 被引量:21
  • 2高峰,郭锦棠,王博,刘意鸥.木材防腐剂氨溶烷基铜铵的制备和防腐性能研究[J].化工进展,2005,24(5):532-536. 被引量:12
  • 3AWPA Standards, A11 - 87, Standard Method of Determining the Leachability of Wood Preservatives [ S]. 1987.
  • 4北原文雄.表面活性剂分析和试验法[M].毛培坤译.北京:北京轻工业出版社,1988.262-264.
  • 5吴国江,王克章.一种新型木材防水专用乳化蜡的研制[J].企业科技与发展,2007(10S):35-36. 被引量:6
  • 6Tsunoda K,Nishimoto K.Fungicidal and termiticidal effectiveness of alkylammonium compounds[C].The 14th Annual Meeting of International Research Group on Wood Preservation.Brisbane,Australia,1983,Document No:IRG/WP/83-3232.
  • 7Sundman C E.Test with ammoniacal copper and alkyl ammonium compounds as wood preservatives[C].The 15th Annual Meeting of International Research Group on Wood Preservation.Sweden,Stockholm,1984,Document No:IRG/WP/84-3299.
  • 8Tang H and Ruddick J N R.Evaluating the potential of amine chemicals for use as wood protecting agents part Ⅰ.Investigation of cation component of quaternary ammonium compounds[C].The 25th Annual Meeting of International Research Group on Wood Preservation.Bali,Indonesia,1994,Document No:IRG/WP/94-30049.
  • 9Wazny J and Rudniewski P.Fungitoxic effect of the quaternary ammonium compounds preservatives against basidiomycetes by agarplate and agar-block methods[C].The 27th Annual Meeting of International Research Group on Wood Preservation.Guadeloupe,France,1996,Document No:IRG/WP/96-30118.
  • 10Creffield J W.A study on the effectiveness of didecydimethylammonium chloride to protect wood from attack by subterranean termites[C].The 24th Annual Meeting of International Research Group on Wood Preservation.Orlando,USA,1993,Document No:IRG/WP/93-30009.