在常温常压下 ,应用电导探针 ,研究了TEMA -E型管壳式换热器壳侧各流路对错流区的气液分布状态的影响。试验结果表明 ,泄漏流对壳侧错流区气液再分配有着直接的影响 ,且在不同的流型下 ,其影响作用大小有所差异。在环状流下 ,A流路的贯通作用使折流板前后对应区域的含气率基本一致 ;泄漏流E使A流路的贯通作用得到明显的削弱。泡状流时 。
Electrical probes were used to examine the influences of each stream on gas and liquid distributions in cross-flow zone of the shell-side in shell-and-tube heat exchanger under normal temperature and pressure. The results show that leakage flow streams have direct effects on the gas-liquid distribution characteristics. The effects are different in different flow regimes. In annular flow the penetrating effect of stream A makes the void fraction same besides a baffle. Stream E will weaken the penetrating effect obviously. In bubble flow the penetrating effect is not obvious.
出处
《河南科技大学学报(自然科学版)》
CAS
2003年第2期48-51,共4页
Journal of Henan University of Science And Technology:Natural Science
基金
河南省教委科研基金资助项目 (1999470 0 0 3 )
教育部出国留学人员科研启动基金资助项目 (2 0 0 1)