期刊文献+

Ultra-Cut biopsy guided by ultrasonography for liver lesions:experience of 392 clinical cases 被引量:1

Ultra-Cut biopsy guided by ultrasonography for liver lesions: experience of 392 clinical cases
下载PDF
导出
摘要 We conducted a retrospective study of the accuracy of liver biopsies in 392 patients with liver lesions. Postbiopsy diagnosis was 297 cases of primary liver cancers, 79 cases of secondary malignant tumors, 2 cases of non-Hodgkin's lymphorna, 10 cases of focal nodular hyperplasia, 2 cases of chronic inflammation, 1 tuberculosis case and 1 schistosomiasis case. Biopsy provided histological diagnosis in 100% of cases, sensibility and specificity of Ultra-Cut biopsy was 98.95% and 100% for the diagnosis of malignancy respectively; positive predictive value, 100% ; negative predictive value, 71.43% ; and accuracy, 98.98 %. We identified no major procedure related complications despite the presence of thrombocytopenia in 37. 5% of cases. Pain was the only reported adverse effect of liver biopsy (10.97%), and 11 patients required analgesics. We concluded that Ukra-Cut liver biopsy was a safe and effective technique, and was invaluable in the investigation and management of patients with liver lesions. We conducted a retrospective study of the accuracy of liver biopsies in 392 patients with liver lesions. Postbiopsy diagnosis was 297 cases of primary liver cancers, 79 cases of secondary malignant tumors, 2 cases of non Hodgkin's lymphoma, 10 cases of focal nodular hyperplasia, 2 cases of chronic inflammation, 1 tuberculosis case and 1 schistosomiasis case. Biopsy provided histological diagnosis in 100% of cases, sensibility and specificity of Ultra Cut biopsy was 98.95% and 100% for the diagnosis of malignancy respectively; positive predictive value, 100%; negative predictive value, 71.43%; and accuracy, 98.98%. We identified no major procedure related complications despite the presence of thrombocytopenia in 37.5% of cases. Pain was the only reported adverse effect of liver biopsy (10.97%), and 11 patients required analgesics. We concluded that Ultra Cut liver biopsy was a safe and effective technique, and was invaluable in the investigation and management of patients with liver lesions.
机构地区 SirRunRunShaxvHospital
出处 《Journal of Zhejiang University Science》 CSCD 2002年第3期374-377,共4页 浙江大学学报(自然科学英文版)
关键词 肝脏损害 超声波检查法 肝脏活体组织检查 肝脏肿瘤 Liver, Neoplasms, Biopsy, Ultrasonography
  • 相关文献

同被引文献1

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部