期刊文献+

激光表面重熔NiTi形状记忆合金组织及腐蚀性能 被引量:7

Microstructure and Corrosion Properties of Laser Surface Remelted NiTi Shape Memory Alloy
下载PDF
导出
摘要 采用 2kWNd :YAG激光器对NiTi合金进行表面重熔处理 ,利用扫描电镜、X射线衍射、X光电子能谱分析重熔层成分和组织结构 ,利用电化学测试研究重熔层耐腐蚀性能。结果表明 :NiTi合金经过激光重熔处理后 ,可得到致密的重熔层 ;根据激光处理参数的不同 ,在重熔层中会出现Ti2 Ni、TiNi3等新相 ,重熔层表面Ti Ni及Ti4 + Ti比显著提高 ; Laser surface remelting was performed on NiTi alloy by a 2kW Nd-YAG laser. The microstructure and chemical compositions of the remelted layer were investigated with SEM, XRD and XPS. The electrochemistry test was employed to evaluate the corrosion resistance of the remelted layer. The results show that a compact remelted layer was formed on the NiTi alloy after laser surface remelting. New phases such as Ti 2Ni and/or TiNi 3 were identified in the remelted layer for different laser parameters. The Ti/Ni and Ti 4+/Ti ratio values of the remelted samples increased significantly as compared to that of the un-treated alloy. The enhanced corrosion resistance was confirmed by electrochemical polarization curves.
出处 《材料热处理学报》 EI CAS CSCD 北大核心 2003年第3期66-69,共4页 Transactions of Materials and Heat Treatment
关键词 NITI合金 激光表面重熔 表面特性 腐蚀 生物材料 NiTi alloy laser surface remelting surface characteristics corrosion biomaterials
  • 相关文献

参考文献17

  • 1刘敬肖,杨大智,徐久军,陈吉华,蔡英骥.离子束合成TiO_2薄膜对医用NiTi合金表面的改性[J].材料研究学报,2001,15(4):445-450. 被引量:19
  • 2褚幼义.形状记忆合金在医学上应用研究的新动向[J].医用生物力学,1995,10(2):1-3. 被引量:4
  • 3杨贤金,崔振铎,赵乃勤,宋文静,曾晟宇,朱胜利,姚康德.Ca/P层对NiTi形状记忆合金生物相容性的影响[J].材料研究学报,2000,14(5):481-484. 被引量:9
  • 4刘敬肖,杨大智.医用NiTi合金表面溶胶-凝胶法制备含磷TiO_2薄膜[J].硅酸盐学报,2002,30(1):45-50. 被引量:11
  • 5Trepanier C, Ztabrizian M, Yahia L H, et al. Improvement of the corrosion resistance of NiTi stents by surface treatments[ A ]. Mater Res Soe Syrup Pine [ C ].1997,459 : 363 - 368.
  • 6Wever D J, Veldhuizen A G, Vries J de, et al. Eletrochemical and surface characterization of a nickel -titanium alloy[J]. Biomaterials, 1998,19: 761 - 769.
  • 7Filip P, Musialek J, Michalek K, M Yen, et al. TiAIV/AI2O3/NiTi shape memory alloy smart composite biomatefials for orthopedic surgery[J]. Materials Science & Engineering, A 1999,273 - 275:769 - 774.
  • 8Villermaux F,Tabfizian M,Yahia L H,et al. Excimer laser treatment of NiTi shape memory alloy biomaterials[J] .Applied Sudace Science, 1997,109 - 110:62 - 66.
  • 9Rondelli G, Vicentini B. Evaluation by electrochemical test of the passive film of equiatomic Ni-Ti alloy also in presence of stress-induced martensite[ J ].Journal of Biomedical Materials Research ,2000,51 ( 1 ) :47 - .54.
  • 10Shih C C, Lim S J, Chung K H,et al. Increased corrosion resistance of stent materials by converting current surface film of polycmstalline oxide into amorphousoxide [ J ]. Journal of Biomedical Materials Research, 2000,52 (2) : 323 - 332.

二级参考文献16

  • 1浦素云 吴云书.植入金属材料在人体环境中腐蚀行为的研究[J].中国生物医学工程学报,1988,7(3):125-125.
  • 2浦素云.-[J].中国生物医学工程学报,1988,7(3):125-125.
  • 3Engbers G.H 王金胜(译).-[J].国外生物医学工程分册,1992,15(1):39-39.
  • 4刘书君.P2O5-SiO2和Li2O-P2O5-SiO2系统凝胶玻璃的制备[J].材料科学与工程,1997,:120-124.
  • 5Zheng X,Biomaterials,2000年,21卷,841页
  • 6Wen H B,Biomaterials,1997年,18卷,1471页
  • 7Yang C Y,J Biomed Mater Res,1997年,37卷,335页
  • 8Wu Kuanghis,The Proc China Japanbilateralsymposium on shapememoryalloys,1997年,229页
  • 9Huang N,J Biomater Appl,1994年,8卷,4期,404页
  • 10浦素云,中国生物医学工程学报,1988年,7卷,3期,125页

共引文献33

同被引文献76

引证文献7

二级引证文献17

相关作者