通过分析某热电厂两台200MW机组近年来高压加热器运行状况,找出高压加热器故障原因,提出相应的技术改造措施,以提高高压加热器投入率,从而提高整个机组的经济性。
This paper made an analysis on the operation conditions of HP heaters of 2×200MW steam turbines in certain thermal power plant, found out the causes for the troubles in HP heaters, and proposed corresponding technical retrofitting measures for improving the availability of HP heater and consequently improving the economic characteristics of the complete unit.