期刊文献+

利用血管内超声视频图像获取冠状动脉截面积曲线 被引量:1

ESTIMATING THE CROSS SECTIONAL AREA OF THE CORONARY ARTERY FROM INTRAVASCULAR ULTRASOUND IMAGES
下载PDF
导出
摘要 利用冠状动脉内超声的视频图像 ,依据相邻帧的连续性自动确定血管内壁的搜索范围 ,结合表征血管内壁平滑性的内部能量和表征超声图像灰阶分布的外部能量 ,采用动态规划方法通过寻找最大能量路径来检测血管内壁的最优包络 ,并由此计算血管的截面积。现提出了一种综合图像灰阶梯度和象素方差的外部能量表示 ,使得冠状动脉截面积曲线的提取方法在鲁棒性、准确性方面较仅用灰阶梯度作为外部能量有了较大的提高。 The cross sectional area of the coronary artery was computed using intra-vascular ultrasound (IVUS) video images. With this method, the search range for the inner arterial wall was firstly determined from the continuity of IVUS video frames. Then the internal and external energy was calculated to describe the smoothness of the arterial wall and the grayscale variation of ultrasound images respectively. Finally, the maximal energy path, which was the optimum contour of the arterial wall, was obtained using a dynamic programming (DP) method. In this paper, a novel form of the external energy was proposed, which integrated the gradient and variant of the grayscale image. In comparison with the traditional external energy form which only counted the image gradient, the robustness and accuracy of this method were apparently improved in the measurement of the cross sectional area of the coronary artery.
出处 《中国生物医学工程学报》 EI CAS CSCD 北大核心 2003年第5期443-447,共5页 Chinese Journal of Biomedical Engineering
基金 上海市青年科技启明星跟踪计划资助项目 ( 0 1QMH14 0 1)
关键词 血管内超声 自动包络检测 动态规划 Blood vessels Dynamic programming Image analysis Ultrasonics
  • 相关文献

参考文献6

  • 1Bom N, Lancée CT, et al. Basic principles of intra-vascular ultrasound imaging[J]. In: Intra-vascular ultrasound imaging (JM Tobis and P Yock, eds) Churchill Livingstone Medical Publishers, New York,1992,7-15.
  • 2Stein IR, Anders HT, et al. Semiautomatic contour detection in ultrasound M-mode images[J ]. Ultrasound in Med. & Bio,2000,26(2) : 287-296.
  • 3Li W, Bosch JG, et al. Semiautomatic frame-to-frame tracking of luminal border from intra-vascular ultrasound[J]. In:Computers in Cardiology, 1992, Los Alamitos: IEEE Computer Society Press, 1992,353-356.
  • 4Gussenhoven WJ, Madretsma S, et al. Detection of vascular morphology by high frequency intra-vascular ultrasonic imaging[J]. Laser Med Sci,1991(6):349-354.
  • 5Li W, Gussenhoven WJ, et al. Validation of quantitative analysis of intra-vascular ultrasound images[J]. Int J Cardiac Imag,1991(6) :247-253.
  • 6Bruining N, yon Birgelen C, et al. ECG-gated ICUS image acquisition combined with a semi-automated contour detection provides accurate analysis of vessel dimension[J ]. In: Computers in Cardiology, 1996, Los Alamitos: IEEE Computer Society Press, 1996,53-56.

同被引文献6

引证文献1

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部