摘要
根据高压断路器分闸运动原理,建立了高压断路器液压机构与压气室的联合运动方程。通过仿真,分析了运动方程中各种力参数对分闸运动特性的影响和操作功特性,并且从理论上提出了调节分闸运动特性的两种途径。
According to the principle of opening operation of high voltage circuit breaker, the joint mathematical model on hydraulic mechanism with arc chamber has been set up. The influence of force parameters on opening velocity characteristic of circuit breaker as well as operation work is researched with dynamic simulation. Two ways are proposed to adjust the opening velocity characteristic.
出处
《高压电器》
CAS
CSCD
北大核心
2003年第5期7-9,12,共4页
High Voltage Apparatus