期刊文献+

200MW机组通流碰磨的非稳定振动分析与诊断 被引量:2

Analysis and Diagnosis for the Unstable Vibration due to the Colliding Wear of 200 MW Turbine Through-flow Parts
下载PDF
导出
摘要 介绍了通辽发电厂1号、3号机组发生的非稳定振动情况(包括振动特点、数据测试),经分析确定为通流部分发生碰磨。开缸检查在中缸和高缸发现碰磨点,缺陷消除后振动得到了改善。 The unstable vibration status(including vibration features and data measured)happened on No.1 & 3 generating sets in Tongliao Power plant are introduced.Through the analyses the colliding wears of through flow parts were determined,The points of colliding wears were discovered in the medium pressure and high pressure cylinders after opening cylinder inspections.The vibration had been improved after the elimination of defects.
作者 赵文新
机构地区 通辽发电总厂
出处 《东北电力技术》 2003年第3期1-5,共5页 Northeast Electric Power Technology
关键词 200MW机组 非稳定振动 通流碰磨 故障分析 故障诊断 汽轮发电机组 MW generating set Unstable vibration Colliding wear of through flow part