摘要
文中针对非接触能量传输系统,对其松耦合变压器的原副边线圈进行串联补偿(SS补偿)。在该种补偿状态下进一步分析了非接触能量传输系统副边输出电流与原边输入电流、输出电压与输入电压、输出功率与输入电压之间的关系。通过仿真,验证了上述分析的正确性。
In view of the contactless power transmission system,primary and secondary coils of the loosely coupled transformer are in series compensation(compensation of SS).Under the state of compensation,the relationship between the output current and the input current,the output voltage and the input voltage,the output power and the input voltage of the non-contact energy transfer system is analyzed.The correctness of the above analysis is verified by simulation.
出处
《通信电源技术》
2016年第4期60-61,共2页
Telecom Power Technology
关键词
非接触能量传输系统
松耦合变压器
串联补偿
the contactless power transmission system
loosely coupled transformer
series compensation