唾液获得性膜对不同桥体材料表面自由能的影响 被引量:2

The influence of acquired salivary pellicle on the surface free energy of different pontic materials
下载PDF
导出
摘要 目的 :评价唾液获得性膜对不同桥体材料表面自由能的影响。方法 :采用接触角测量仪检测4种桥体材料 (Co -Cr合金、Au -Pt合金、纯Ti以及Vita95瓷 )表面形成唾液获得性膜前后试件的接触角并计算表面能。结果 :制备唾液获得性膜后所有受测材料的表面自由能极性分量升高 ,自由能总量趋于一致。结论 :唾液获得性膜会改变修复材料的表面属性 ,使不同材料表面自由能之间的差异减小。 AIM:To investigate the effect of acquired salivary pellicle on the surface free energy of different pontic materials. METHODS: Measure the contact angle to calculate the surface free energy of four pontic materials before and after the formation of acquired salivary pellicle. RESULTS: The pellicle increased the polar component of surface free energies of all materials markedly and had a homogenizing effect in terms of the surface free energy. CONCLUSION: The acquired salivary pellicle can change the surface properties of dental materials and can make the difference among dental materials smaller.
出处 《牙体牙髓牙周病学杂志》 CAS 2003年第9期495-497,共3页 Chinese Journal of Conservative Dentistry
关键词 唾液获得性膜 桥体材料 表面自由能 acquired salivary pellicle bridge pontic material surface free energy
  • 相关文献

参考文献9

二级参考文献13

  • 1王松灵,中华口腔医学杂志,1994年,29卷,57页
  • 2王松灵,Int J Oral Maxillofac Surg,1993年,22卷,362页
  • 3王松灵,中华口腔医学杂志,1990年,25卷,288页
  • 4张锡泽,口腔颌面外科学,1982年,42页
  • 5宋华杰,学位论文,2000年
  • 6张开,高分子界面科学,1997年
  • 7Wu Souheng,Polymer Interface and Adhesion,1982年
  • 8周皓,1988年
  • 9吕碧昌,机电基础标准实用简明手册,1991年,133页
  • 10Verran J,J Prosthet Dent,1997年,77卷,5期,535页

共引文献109

同被引文献15

  • 1朱国威,杨晓红,陈丽娅,陈林.非贵金属烤瓷冠修复后牙龈组织和血液中镍铬元素含量分析[J].华西口腔医学杂志,2004,22(4):284-286. 被引量:71
  • 2马守治,闫福华,程辉,章少萍,赵欣.暂时冠对牙周环境的影响[J].口腔医学研究,2004,20(5):526-528. 被引量:6
  • 3Riev J. Friction and Wear on Implant Materials, Biomaterials, 1994(12): 139-144.
  • 4Browne M, Gregson PJ, Surface Modification of Titanium Alloy Implants, Biomaterials, 1994, 15(11): 894-898.
  • 5Kononer Mo Lavonius ET Kivilahti 3K, SME observiation on stress Corrosion. Crucking of Commercially Pure titanium in a topiocal Fluoride Solution, Dental Materials, 1995:11, 269.
  • 6D Sheeja, B K Tay, S P Lau, Tribological characterisation of diamond-like carbon coatings on Co-Cr-Mo alloy for orthopaedic applications, Surface and Coatings Technology, (2001) 410:146-147.
  • 7K N Strafford. The efficiency of uncoated and coated tool systems in the machining of low carbon steel assessed through cutting force measurements[M]. Surface and Coatings Technology, 1995:706-711.
  • 8S Kobayashi, Y Ohgoe, K. Ozeki, et al. Diamond-like carbon coatings on orthodontic archwires[J]. Diamond and Related Materials, 2005, 14(3): 1091.
  • 9DK Owens, RC Wendt. Estimation of the surface free energyofpolymers[J]. Appl. Polym, 1969, 13(6): 1741.
  • 10M Zenkiewicz. Adhesion and Modification of surface layer of Macromolecular materials [M]. Scientific-Technical Publishers, 2000:125.