摘要 本文在综合厂址、近区域及区域地震地质资料的基础上,根据有关规范的要求,采用地震构造法、最大历史地震法和概率法分别计算了沈阳2×200兆瓦低温核供热站厂址的极限安全地震动SL-2,计算结果分别为200Gal、125Gal和170Gal。取三者最大值,厂址SL-2应当是200gal。厂址基岩地面运动SL-2水平向加速度反应谱取确定性法和概率法计算曲线的外包线作为用于厂址的基岩加速度反应谱。 Based on synthetic analysis of regional and near-regional seismogeological data, the ultimate safe ground motion (SL-2) for the site was obtained by the seismo-tectonic method, the probability method and the maximum historical earthquake method in accordance with the rules of the nuclear safe guidelines. The calculating results are 200Gal, 170Gal and 125Gal respectively. We take the maximum value of them as ultimate safe ground motion(SL-2). We also think it is suitable to take the enveloping curve of the horizontal acceleration response spectra corresponding to SL-2 based on probabilistic method and deterministive method as the acceleration response spectra of the basement rock site.
出处 《地震工程与工程振动》 CSCD 北大核心 2003年第4期78-82,共5页 Earthquake Engineering and Engineering Dynamics
基金 辽宁省科委科技攻关项目(2002231001)
关键词 核电厂 极限安全地震动 厂址选择 地震构造法 最大历史地震法 概率法 基岩加速度反应谱 nuclear power plant limiting safe seismic motion shenyang city
  • 相关文献

参考文献7

  • 1钟以章,王国新.辽宁核电站温坨子厂址设计墓准地面运动SL_2和SL_1的确定[J].中国地震,1994,10(1):54-61. 被引量:2
  • 2辽宁省地震局.辽宁省地震目录[M].辽宁大学出版社,1985..
  • 3辽宁省地矿局.辽宁省区域地质志[M].地质出版社,1985..
  • 4.HAF0101(1).核安全法规核电厂厂址选择中的地震问题[S].,..
  • 5.(GB17741-1999).国家标准工程场地地震安全性评价技术规范[S].,..
  • 6HAF0101(1).核安全法规核电厂厂址选择中的地震问题[S].[S].,..
  • 7(GB17741—1999).国家标准工程场地地震安全性评价技术规范[S].[S].,..

共引文献1

同被引文献10

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部