摘要 To overcome the disadvantages of conventional DGA (dissolved gas-in-oil)analysis using gas chromatography and other electrochemical sensors, initial researches werecompleted to realize on-line monitoring of dissolved gas-in-oil of power transformers using FTIR(Fourier Transform InfraRed) spectroscopy. Gas cell method is used to determine the characteristicabsorption peaks of each diagnostic gas; simple and novel devices and procedures were designed inorder to get measurable samples and spectra of mixed diagnostic gases with known concentration aretaken using long optical path gas cell. The range of wavelength is estimated to be 3.0-13.9 mum fromexperimental spectra data. Hence the corresponding sampling frequency range should be in 536-4288Hz and usable optical materials are suggested. It is concluded that a resolution of 10 cm^(-1) maywell satisfy the monitoring of all diagnostic gases and water content except hydrogen, and thelowest detection limit may be as low as 2Xl0^(-8) to acetylene with a 2.4-meter-long optical length. To overcome the disadvantages of conventional DGA (dissolved gas-in-oil)analysis using gas chromatography and other electrochemical sensors, initial researches werecompleted to realize on-line monitoring of dissolved gas-in-oil of power transformers using FTIR(Fourier Transform InfraRed) spectroscopy. Gas cell method is used to determine the characteristicabsorption peaks of each diagnostic gas; simple and novel devices and procedures were designed inorder to get measurable samples and spectra of mixed diagnostic gases with known concentration aretaken using long optical path gas cell. The range of wavelength is estimated to be 3.0-13.9 mum fromexperimental spectra data. Hence the corresponding sampling frequency range should be in 536-4288Hz and usable optical materials are suggested. It is concluded that a resolution of 10 cm^(-1) maywell satisfy the monitoring of all diagnostic gases and water content except hydrogen, and thelowest detection limit may be as low as 2Xl0^(-8) to acetylene with a 2.4-meter-long optical length.
出处 《Journal of University of Science and Technology Beijing》 CSCD 2003年第4期65-68,共4页 北京科技大学学报(英文版)
关键词 FTIR power transformer dissolved gas-in-oil on-line monitoring INFRAREDSPECTRA FTIR power transformer dissolved gas-in-oil on-line monitoring infraredspectra
  • 相关文献

同被引文献16

  • 1徐文,王大忠,周泽存,陈珩.结合遗传算法的人工神经网络在电力变压器故障诊断中的应用[J].中国电机工程学报,1997,17(2):109-112. 被引量:77
  • 2玄光男 程润伟.遗传算法与工程设计[M].北京:科学出版社,2000..
  • 3Zhang Y,Ding X,Liu Y,et al.An artificial neural network approach to transformer fault diagnosis[J].IEEE Trans Power Deliv,1997,12(4):1836-1841.
  • 4Kirtley J L, Jr W H, Hagman B C. Monitoring the health of transformer[J]. Comp App Power, 1996,63(2): 18- 23.
  • 5Su Q, Mi C, Lal L L, et al. A fuzzy dissolved gas analysis method for the diagnosis of multiple incipient faults in a transformer [J]. IEEE Transactions on Power Systems,2000,15(2):593-598.
  • 6Lin C E,Ling J M,Huang C L. An expert system for transformer fault diagnosis and maintenance using dissolved gas analysis.[J].IEEE Trans Power Deliv,1993,8(1):231-238.
  • 7Huang Y C M,Yang H T M,Huang C L. Developing a new transformer fault diagnosis system through evolutionary fuzzy logic[J].IEEE Trans Power Deliv,1997,12(2):761-767.
  • 8Yang H T,Liao C C.Adaptivefuzzy diagnosis system for dissolved gas analysis of power transformers[J].IEEE Trans Power Deliv,1999,14(4):1342-1350.
  • 9许仪勋,陆拯,郭志忠.基于遗传算法的电力系统分层信息故障诊断方法[J].继电器,2000,28(10):15-18. 被引量:22
  • 10孙辉,李卫东,孙启忠.判决树方法用于变压器故障诊断的研究[J].中国电机工程学报,2001,21(2):50-55. 被引量:46