期刊文献+

气体流量量值溯源体系探讨 被引量:15

Traceability system about gas flow
下载PDF
导出
摘要  介绍了气体流量量值溯源中的关键环节,并对各环节的国际发展趋势进行了简单介绍. The gas flow test facilities and its traceability are described in the paper. The primary standards of gas flow are piston prover or bell prover generally. The secondary standards are turbine meters or sonic nozzles. The paper also gives the introduction about the comparison of gas flow between different facilities.
作者 王池
出处 《中国计量学院学报》 2003年第3期170-173,共4页 Journal of China Jiliang University
  • 相关文献

参考文献4

  • 1[1]Bodo Mickan+, Rainer Kramer+, et al. PIGSAR-THE EXTENDED TEST FACILITY AND NEW GERMANNATIONAL PRIMARY STANDARD FOR HIGH PRESSURE NATURAL GAS, published in Washington USA FLOMEKO'2002.
  • 2[2]Wolfram Bremser, Werner Hsselbarth, et al. Uncertainty Analysis and Long-Term Stability Investigationof the German Primary High-Pressure Natural Gas Test Facility pigsar, published in Groningen, The Netherlands FLOMEKO'2003.
  • 3[3]R. van den Brink, M P van der Beek, et al. "QUADRATIC WEIGHING", APPLIED IN HARMONIZATION, A TOOL TO COMPARE THE PERFORMANCE OF TEST-FACILITIES published in Groningen, The Netherlands; FLOMEKO'2003.
  • 4[4]John D. Wright, WHAT IS THE "BEST" TRANSFER STANDARD FOR GAS FLOW? published in Groningen, The Netherlands FLOMEKO'2003.