期刊文献+

Application of Polyaniline Incorporated Carbon Particles Coated Platinum Electrode in Coulometric Titration to Determination of Polyisoprene Alcohol

Application of Polyaniline Incorporated Carbon Particles Coated Platinum Electrode in Coulometric Titration to Determination of Polyisoprene Alcohol
下载PDF
导出
摘要 The feasibility of using electrodes modified with polyaniline incorporated carbon particles films for improving the precision of coulometric titration is demonstrated. The problem of large deviation produced during determining polyisoprene by coulometric titration with direct titration technique(double Pt electrodes indicating electrode) has been solved. In the titration process, polyisoprene alcohol, an electro-inactive species, is adsorbed on the surface of the bare Pt electrode, which inhibits the electrode reaction of Br - and Br 2. Therefore, when the titration reaches the end-point, the detected current will slowly change with time, which can make the repeatability of end-point poor. The atomic force microscopic images show the morphology of the electrode surface of adsorbing polyisoprene alcohol. The application of the chemically modified electrode instead of the bare Pt electrode to indicating the end-point has been investigated. The results show that the Pt electrode coated with polyaniline incorporated carbon particles films is an excellent indicator electrode. This electrode has advantages that the indicating signals are sharp and repeatable at end-point. The precision and the accuracy of the determination of polyisoprene alcohol are satisfactory. The feasibility of using electrodes modified with polyaniline incorporated carbon particles films for improving the precision of coulometric titration is demonstrated. The problem of large deviation produced during determining polyisoprene by coulometric titration with direct titration technique(double Pt electrodes indicating electrode) has been solved. In the titration process, polyisoprene alcohol, an electro-inactive species, is adsorbed on the surface of the bare Pt electrode, which inhibits the electrode reaction of Br - and Br 2. Therefore, when the titration reaches the end-point, the detected current will slowly change with time, which can make the repeatability of end-point poor. The atomic force microscopic images show the morphology of the electrode surface of adsorbing polyisoprene alcohol. The application of the chemically modified electrode instead of the bare Pt electrode to indicating the end-point has been investigated. The results show that the Pt electrode coated with polyaniline incorporated carbon particles films is an excellent indicator electrode. This electrode has advantages that the indicating signals are sharp and repeatable at end-point. The precision and the accuracy of the determination of polyisoprene alcohol are satisfactory.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2003年第4期390-394,共5页 高等学校化学研究(英文版)
基金 Supported by the Science and Technology Comm ission of Henan Province and Education Com mission of HenanProvince
关键词 Surface chemisorption PAn-CP CME Coulometric titration DETERMINATION Surface chemisorption, PAn-CP CME, Coulometric titration, Determination
  • 相关文献

参考文献15

  • 1Dong S J,Che G L,Xie Y W.Chemically Modified Electrodes,Science Press,Beijing,1995, 362.
  • 2Hafez M A H, Kenawy I M M , Akl M A , et al. Talanta, 2001, 53, 749.
  • 3Luo H X , Shi Z J, Li N Q , et al. Chem J Chinese Universities, 2000, 21(9), 1372.
  • 4Joseph W, Lu Z L. Anal Chem , 1990, 62, 826.
  • 5Keiichi K , Setsuko Y , Hironori R,et al. Anal Chem ,2001, 73, 1605.
  • 6Maryann P O, Halloran M P, George G G. Talanta,2001, 55, 605.
  • 7Narasimha C V , Rao M K , Chakraborty, TOB Res,1956, 4, 53.
  • 8Bilinsk W B, Stedman R L, J Assoc Offic Agr Chemists ,1962, 45, 532.
  • 9Woollen B H, Jones D H , J Chromatogr , 1971, 61,180.
  • 10Severson R F , Ellington J J, Arrendale R F , et al. J Chromatogr ,1997, 139, 269.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部