分析了住宅火灾的特点 ,指出住宅喷淋系统的设置部位不能任意应用和演绎。介绍了住宅喷淋系统的给水方式 ,喷头的选用 ,设计作用面积和供水时间的确定 ,以及喷头的工作压力和安装要求。
The special characters of fire accident in dwelling houses were discussed, which indicating that the location to install the sprinkling fire control system would not be arbitrarily. The suitable water supplying schemes and nozzles for proper choice for dwelling house sprinkling system are presented. Also the calculation of the service area and sprinkling duration, the required water head of the nozzles and the installation attentions in design and construction of sprinkling system are indicated in this paper.