期刊文献+

四角切圆燃烧锅炉屏式再热器超温研究 被引量:2

STUDY ON OVER-TEMPERATURE OF PLATEN TYPE REHEATER FOR BOILERS WITH FOUR CORNER TANGENTIAL FIRING
下载PDF
导出
摘要 通过试验得到屏式再热器的壁温分布 ,分析试验结果找出超温的再热器管。结合锅炉炉膛出口水平烟道的烟温分布 ,认为超温主要为水平烟道烟温偏差所致 ,对此提出了更换材质、加大三次风的反切角度。 Through tests, the wall temperature distribution of platen type reheater has been obtained, and the over-temperature of reheater tube being known from the analysis of test results. Combined with the flue gas temperature distribution of outlet horizontal gas duct from the furnace of boiler, it is considered that the cause resulting in over-temperature is mainly due to temperature deviation in the horizontal flue gas duct, and the correspanding retrofit of equipments and operational adjustment being put forward.
作者 刘尧平 娄春
机构地区 华中科技大学
出处 《热力发电》 CAS 北大核心 2003年第10期38-40,55,共4页 Thermal Power Generation
  • 相关文献

参考文献6

  • 1热工研究院.利港电厂1号炉大屏过热器试验报告[R].,1995..
  • 2热工研究院.秦岭电厂4号炉(DG670/140-8型)燃烧器改造及燃烧调整试验报告[R].,1992..
  • 3中国电机工程学会.600 MW级机组锅炉学术讨论会论文集[C].,1998..
  • 4热工研究院.利港电厂1号炉大屏过热嚣试验报告[R].,1995..
  • 5中国电机工程学会.[A]..600 Mw级机组锅炉学术讨论会论文集[C].,1998..
  • 6热工研究院.秦岭电厂4号炉(DG670/140-8型)燃烧器改造及燃烧调整试验报告[R].,1992..