摘要
简要分析了鄯善 3 0× 1 0 4 m3/d(标 )轻烃回收装置原丙烷冷却系统不能适应工艺的原因 ,介绍了表面蒸发式空冷器的工作原理、结构特点及其在轻烃回收装置中的应用效果 。
The failure cause of the old propane cooling system of a 30×10 4m 3/d (standard) light hydrocarbon recovery unit in Shanshan Oil Production Plant was analyzed, the working principles, structure characteristics of the surface evaporating air condenser and its application result in the light hydrocarbon recovery unit were presented, and a comparison was made between the surface evaporating air condenser and the old propane cooling system in property.
出处
《化工机械》
CAS
2003年第5期279-281,共3页
Chemical Engineering & Machinery