摘要 为了实现利用FTIR光谱仪进行野外地物光谱发射率的测量,针对D&P公司生产的Model-101型便携式FTIR光谱仪,讨论了仪器的定标原理,给出了样品的光谱辐射计算公式.采用低发射率反射板测量环境辐射,从而可以方便、快捷地计算出样品的发射率,并给出了相应的修正方法.样品实测结果表明,修正后的光谱发射率曲线与标准光谱发射率曲线具有很好的一致性. A portable Fourier transform infrared spectrometer developed by D&P is used for the field measurement of emissivity. The method of calibration is discussed in detail, and the calibrated spectral radiance is given. A reflective plate which has low emissivity is used to measure the downwelling radiance, thus the emissivity of samples can be calculated. The method of error correction and samples of measurement results are given.
作者 王霞 金伟其
出处 《北京理工大学学报》 EI CAS CSCD 北大核心 2003年第4期405-407,418,共4页 Transactions of Beijing Institute of Technology
关键词 FTIR光谱仪 光谱发射率 野外测量 Fourier transform infrared(FTIR) spectrometer spectral emissivity field measurement
  • 相关文献

参考文献5

  • 1林沝 吴平平 周文敏 等.实用傅立叶变换红外光谱学[M].北京:中国环境科学出版社,1991..
  • 2Salisbury J W, D'Aria D M. Emissivity of terrestrial materials in the 8- 14 μm atmospheric window [J].Remote Sensing Environ, 1992(42): 83-106.
  • 3Salisbury J W, D'Aria D M. Emissivity of terrestrial materials in the 3- 5/μm atmospheric window [J].Remote Sensing Environ, 1994(47): 345-361.
  • 4Hook S, Kahle A B. μFTIR-A new field spectrometer for validation of infrared data [J].Remote Sensing Environ, 1997, 70 : 175- 186.
  • 5Wang Xia, Gao Zhiyun, Zhang Jianyong, et al.Research on calibration method of three band infrared integrated radiometer[J]. SPIE, 2002, 4927:133-138.

同被引文献15

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部