摘要 对TiNi形状记忆合金在体外及体内两种生理环境中的耐蚀性研究进行了综述 ,阐述了其阳极极化性能、孔蚀发生机理及表面状态、模拟介质及合金成份对耐蚀性的影响 。 The study on corrosion resistance of TiNi shape memory alloy is summarized in two physiological environments including in Vitro and in Vivo. The anodic behavior, mechanism of pitting corrosion and effects of surface,artificial solution and alloy composition on corrosion resistance are discussed. In addition, the development tendency of TiNi shape memory alloy is reviewed in the end of the paper.
出处 《腐蚀科学与防护技术》 CAS CSCD 北大核心 2001年第3期152-155,共4页 Corrosion Science and Protection Technology
基金 辽宁省自然科学基金资助项目! (972 2 10 )
关键词 TINI合金 形状记忆合金 耐蚀性 研究进展 生理环境 TiNi shape memory alloy,physiological environment,corrosion resistance
  • 相关文献

参考文献13

二级参考文献40

共引文献91

同被引文献14

  • 1XIE Miao(薛淼),JIA Wei-tao(贾为涛).形状记忆合金的医学应用[J].Journal of Biomedical Engineering(生物医学工程学杂志),1987,4(2):130-134.
  • 2[2]GU Han-qing(顾汉卿),XU Guo-feng(徐国风).Biomedical Materials (生物医学材料学)[M].Tianjin: Tianjin Science and Technology Translation Press,1993.356-358.
  • 3[3]Kazuhiko Endo.Corrosion resistance of Ni-containing alloys [A].Corrosion and Protection 126th Conference [C].Tokyo,1999.36-45.
  • 4[4]Takata E.Corrosion of dental material [A].Corrosion and Protection 126th Conference [C].Tokyo,1999.11-18.
  • 5[5]Lucas L C,Buchanan R A,Lemons J E,et al.Susceptibility of surgical cobalt-base alloy to pitting corrosion [J].Journal of Biomedical Materials Research,1982,16: 799-810.
  • 6[6]PU Su-yun(浦素云).Metallic Implant Materials and Corrosion (金属植入材料及其腐蚀) [M].Beijing: Beijing University of Aviation and Spaceflight,1990.62-66.
  • 7[7]CAO Chu-nan(曹楚南).Electrochemical Corrosion (腐蚀电化学)[M].Beijing: Chemical Industry Press,1994.59-60.
  • 8[8]Masayuki Itagaki,Atsushi Nishikata,Tooru Tsuru.Cathodic reduction of passive films on cobalt in a neutral solution [J].Corrosion Engineering,1991,40(4): 254-260.
  • 9[9]Dutta R S,Madangopal K,Gadiyar H S,et al.Biocompatibility of Ni-Ti shape memory alloy [J].British Corrosion Journal,1993,28(3): 217-221.
  • 10[11]WANG Xiang-hui,ZHANG Feng,LI Chang-rong,et al.Improvement of blood compatibility of artificial heart valves via titanium oxide film coated on low temperature isotropic carbon [J].Surface and Coatings Technology,2000,128-129: 36-42.

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部