摘要
针对自动喷水灭火系统的安装过程 ,结合近年来在施工及工程验收中所遇到的问题 ,从消防水泵的设置 ,喷头与管道的正确安装等方面作了总结 ,并指出设计和施工部门应严格把关 。
In view of the issues encountered in construction and acceptance of the automatic fire system in this paper discussion is carried out in terms of the setting of fire fighting pump, correct installation of spray and pipe. Author points out that through strict quality control the effective roles of this system can be developed.
出处
《山西建筑》
2003年第16期59-60,共2页
Shanxi Architecture
关键词
自动喷水灭火系统
消防
水泵
工程验收
工程施工
automatic sprinkling fire system, fire fighting pump, construction quality